Transcript
General Technical Specifications Medical CE-mark: The CE-mark indicates that Interacoustics A/S meets the requirements of Annex II of the Medical Device Directive 93/42/EEC. Approval of the quality system is made by TÜV - identification no. 0123. IEC 60601-1, Class I, Type B (using UPS400 external power supply) IEC 60601-1-2 EMC: IEC 60645-1/ANSI S3.6 , Type 3 Tone audiometer Audiometer: UPS400 External power supply Power: See description in separate Service Manual 2xT1A + 1xT2A located on PCB Fuses: Operation environment: Temperature: 15 – 35 C 30 – 90% Rel. Humidity: Transport temperature:: -20-50°C 0-50°C Storage temperature: Warm up time: 3 minutes at room temperature (20 C). Standards: Safety: Functions Signal sources: Tone: Masking: Inputs: Outputs: Pat. response Power UPS400 Earphone Right / Left: Bone conductor: Insert masking phone MTP10: Printer: RS232 11 pure tone and warble test frequencies in the range of 125 – 8000Hz Narrow band noise, in 11 bands. White noise. Connection for patient response switch. Response lamp will light when activated. Connection for external power supply. Can be selected to be either standard earphones or insert phones by pressing shift Right/Left. Masking in Right or Left earphone can be selected. For use of CIR22. Use of MTP10 as printer device Laser printer with HP GL2 language Ink jet or matrix printer using IBM mode (optional) Desk jet printers using HP PCL L3 language (optional) Input/output for computer communication. See separate section in Service Manual for programming details Operator to patient communication. 10 – 110 dB continuously adjustable on the operation panel Patient Communication: Talk Forward: Attenuator: -10 to 120 dB in 1 or 5 dB steps for tone and speech. The upper 20 dB is accessed by pressing the +20 dB button. 0 – 110 dB in 1 or 5 dB steps for masking noise. Silent touch switch for soft presentation of signals. Tone lamp will light when activated. Tone is presented by activation of Tone Switch. Manual: Tone is interrupted by activation of Tone Switch. Reverse: Single pulse or automatic pulsing with selectable on/off times of Pulse: 250 – 5000ms. Patient controlled Hughson-Westlake test according to ISO 8253-1 with automatic storing of the threshold values in the internal memory. Patient response is open for 2 seconds after signal presentation. 2 out of 3 or 3 out of 5 correct responses can be selected. Pure tone or narrow band stimulation. Fixed frequency. Continuous and pulsed tone. If selected, it will indicate end of automatic test. With automatic score calculation (5 dB included for SISI: familiarisation). Binaural pure tone or speech stimulation. Stenger: Tone Switch: Tone presentation: Auto Threshold: Békésy: Buzzer: Special test types: AD226 Service Manual 2