Download CONDITIONING

Transcript
DIAGNOSTIC
Case Study
Mark Lemay
2006 Chevrolet Cobalt A/C
This vehicle came in for a customer complaint of insufficient cooling from
the A/C System. The air from the vent was cool but not cold.
A
quick visual check revealed no
problems and since this vehicle
has a pressure sensor in the high
side line, a scan tool was hooked
u p a n d t h e p re s s u re wa s ta ke n
before the vehicle was started up.
(Fig. 2) The ambient air temperature was 73°F and the system
pressure measured at 74 psi.
Test procedure
T h i s t e s t ve r i f i e s t h a t t h e sys tem has a minimum refrigerant
charge. The system met the specification in the service manual.
Next the vehicle was started, the
centre duct temperature and the
high and low side pressures were
taken using a manifold gauge
set. The readings were then compared to the performance chart
(Fig. 3) from the service manual.
All readings were taken with the
doors closed, the A/C set to high
b l owe r a n d re c i rc u l a t i o n m o d e
selected. The driver’s door window was opened 6 inches as per
the test procedure.
p re s s u re, b u t t h e d u c t t e m p e rature was a little high.
Next step
With no clea r d i re c t i o n , a t e m p e r a t u r e t e s t w a s c a l l e d f o r.
Te m p e r a t u r e t e s t i n g i n v o l v e s
ta k i n g re a d i n g s a t t h e eva p o r ator and condenser inlet and
outlet lines and comparing them
to a c h a r t . ( F i g . 1 a n d F i g . 4 ) .
This test is conducted with all
the doors open, the vehicle ex p o s e d t o s u n l o a d i f p o s s i b l e,
the engine slightly above idle
(around 1000 rpm) and the A/C
turned to the MAX position.
When tested in this manner our
vehicle readings were as follows:
condenser inlet temperature 135°F,
condenser outlet temperature 72°F,
evaporator inlet temperature 37°F
and the evaporator inlet temperature measured 31°F. When compared to the charts this indicates
that the system is undercharged.
Leak test
An electronic leak detector was
used and the hoses, connections
and heat exchangers were carefully
checked with no signs of leaks evident. The gauges were removed and
a dye was injected into the system.
Our vehicle measured a duct
temperature of 57°F, a low side
pressure of 27 psi and a high
side pressure of 196 psi. When
these reading were compared
to the charts, the readings were
just within the system limits on
Below 35%
25-29ºC (76-85ºF)
Fig.2
2
35-50%
above 50%
I AIR CONDITIONING SUPPLEMENT 2011 I autosphere.ca
Fig. 1
172-234kPa
(25-34 psi)
179-241 kPa
(26-35 psi)
186-248 kPa
(27-36 psi)
999-1371 kPa
(145-199 psi)
1067-1433 kPa
(155-208 psi)
1123-1543 kPa
(163-224 psi)
10ºC (50ºF)
10ºC (50ºF)
12ºC (52ºF)