Download CONDITIONING
Transcript
DIAGNOSTIC Case Study Mark Lemay 2006 Chevrolet Cobalt A/C This vehicle came in for a customer complaint of insufficient cooling from the A/C System. The air from the vent was cool but not cold. A quick visual check revealed no problems and since this vehicle has a pressure sensor in the high side line, a scan tool was hooked u p a n d t h e p re s s u re wa s ta ke n before the vehicle was started up. (Fig. 2) The ambient air temperature was 73°F and the system pressure measured at 74 psi. Test procedure T h i s t e s t ve r i f i e s t h a t t h e sys tem has a minimum refrigerant charge. The system met the specification in the service manual. Next the vehicle was started, the centre duct temperature and the high and low side pressures were taken using a manifold gauge set. The readings were then compared to the performance chart (Fig. 3) from the service manual. All readings were taken with the doors closed, the A/C set to high b l owe r a n d re c i rc u l a t i o n m o d e selected. The driver’s door window was opened 6 inches as per the test procedure. p re s s u re, b u t t h e d u c t t e m p e rature was a little high. Next step With no clea r d i re c t i o n , a t e m p e r a t u r e t e s t w a s c a l l e d f o r. Te m p e r a t u r e t e s t i n g i n v o l v e s ta k i n g re a d i n g s a t t h e eva p o r ator and condenser inlet and outlet lines and comparing them to a c h a r t . ( F i g . 1 a n d F i g . 4 ) . This test is conducted with all the doors open, the vehicle ex p o s e d t o s u n l o a d i f p o s s i b l e, the engine slightly above idle (around 1000 rpm) and the A/C turned to the MAX position. When tested in this manner our vehicle readings were as follows: condenser inlet temperature 135°F, condenser outlet temperature 72°F, evaporator inlet temperature 37°F and the evaporator inlet temperature measured 31°F. When compared to the charts this indicates that the system is undercharged. Leak test An electronic leak detector was used and the hoses, connections and heat exchangers were carefully checked with no signs of leaks evident. The gauges were removed and a dye was injected into the system. Our vehicle measured a duct temperature of 57°F, a low side pressure of 27 psi and a high side pressure of 196 psi. When these reading were compared to the charts, the readings were just within the system limits on Below 35% 25-29ºC (76-85ºF) Fig.2 2 35-50% above 50% I AIR CONDITIONING SUPPLEMENT 2011 I autosphere.ca Fig. 1 172-234kPa (25-34 psi) 179-241 kPa (26-35 psi) 186-248 kPa (27-36 psi) 999-1371 kPa (145-199 psi) 1067-1433 kPa (155-208 psi) 1123-1543 kPa (163-224 psi) 10ºC (50ºF) 10ºC (50ºF) 12ºC (52ºF)