Download 1978 , Volume , Issue May-1978
Transcript
Microprocessor-Controlled Harmonic Heterodyne Microwave Counter also Measures Amplitudes The new harmonic heterodyne frequency measuring technique provides wide F M tolerance, high sensitivity, and automatic amplitude discrimination. Simultaneous measurement of input amplitude is optional. by Ali Bologlu and Vernon A. Barber AUTOMATIC MICROWAVE FREQUENCY mea surements to 18 GHz and beyond have generally been done using one of two frequency down-conver sion techniques, the transfer oscillator or the hetero dyne converter (see box, page 5). In a new micro wave counter, Model 5342 A (Fig. 1), a new downconversion technique, called harmonic heterodyne conversion, provides many of the advantages of both traditional methods while significantly reducing cost. Among these advantages are wide FM tolerance, high input sensitivity, and automatic amplitude dis crimination. The new technique requires only one microwave component, a sampler, and relies on a microprocessor to perform the required computations, thereby eliminating a good deal of digital hardware and its associated expense. The microprocessor also adds to the counter's power and versatility by making it pos sible to manipulate the measured data. An easy-to-use keyboard permits the operator to define frequency offsets or measure frequency deviations. An amplitude measurement option provides simultane ous measurements of input signal level and input frequency for the first time in a microwave counter. Model 5342A measures frequency from 10 Hz to 18 GHz with a resolution of 1 Hz. It has an 11-digit display. With the amplitude measurement option, the user can see input level displayed in dBm with 0.1-dB resolution and ±1.5-dB accuracy, and frequency can be displayed simultaneously with 1-MHz resolution. Harmonic Heterodyne Conversion Fig. 2 is a simplified block diagram of the harmonic heterodyne technique. All of the harmonics of an internal oscillator are simultaneously mixed with the unknown signal by the sampler. The output of the sampler consists of sum and difference frequencies produced by each harmonic of the internal oscillator mixing with the unknown. The internal oscillator, a programmable frequency synthesizer locked to the counter's time base, is incremented in frequency until one of the outputs of the sampler is in the counting range of the low-frequency counter. The IF detector detects when the IF (intermediate frequency) is in the range of the low-frequency counter and sends a signal that causes the synthesizer control to stop increment ing the frequency of the synthesizer. The IF is then counted by the low-frequency counter. The unknown frequency can be determined from the relation: fx = Nf, ± f,IKl Cover: An easy-to-use key board puts the micropro cessor-based Model 5342A Microwave Frequency Count er through its paces. This new counter measures fre quencies and (optionally) amplitudes, with or without offsets, up to 18 GHz, and has extensive built-in self-test facilities. In this Issue: Microprocessor-Controlled Harmonic Heterodyne Microwave Counter also Measures Amplitudes, by Ali Bologlu and Vernon A. Barber page 2 A Technique that Is Insensitive to FM for Deter mining Harmonic Number and Sideband, by Luiz Peregrino, page 13. Generating High-Speed CRT Displays from Digital Data, by Arnot L Ellsworth and Kunio Hasebe . L a b o r a t o r y N o t e b o o k page 17 page 24 Swept-Frequency Measurements of High Levels of Attenuation at Microwave Frequencies ©Hewlett-Packard Company. 1978 Printed in U.S.A. © Copr. 1949-1998 Hewlett-Packard Co.