Download MN01029
Transcript
Section 4 – Troubleshooting Table Problem Cause Air passing through meter. Over-registration (registering more volume than pass Calibrator out of adjustment. ing through meter). Leaky valve in prover system (during test run). Under-registration (register- Mechanical friction in meter. ing less volume than passing through meter). Binding or misalignment in driven accessories. Loose gear train or slipping drives. Calibrator out of adjustment. Oversize clearances in meter. Product being eliminated through vent line. Product being eliminated Air eliminator cylinder seal damaged. through vent line. Air eliminator float ruptured. Foreign particles on cylinder sealing surfaces. System fails to shut off Linkage out of adjustment between set-stop counter and valve. properly after delivering preset quantity. Improper setting of “Minimum Setting” in set-stop counter. Mechanical obstruction in valve. Defective pushbutton set-stop counter. Plugged orifice. Strainer clogged. Restricted product flow through meter. Butterfly valve in air eliminator restricting flow. Back pressure or manual valves do not open. Mechanical obstruction in meter. Pump not operating (pressure system). No product. Air being eliminated from product. Pump undersized. Pump not operating properly. System leaks after shutdown. Linkage out of adjustment. Defective main seat seal in valve. Foreign matter holding main valve seat open. Drive coupling defective. Large numeral counter or ticket printer not operating Internal problems. satisfactorily. Page 18 • MN01029 Remedy Check air eliminator. Readjust calibrator. See MN01028, Pg. 4. Repair prover valve and rerun test. Check all meter clearances. See Pgs. 12 through 13. Check bearings for tightness. Inspect accessories. Repair or replace. Repair or replace. Readjust calibrator. See MN01028, Pg. 4. Check meter clearances. See Pg. 12. See below. Replace cylinder seal. Replace float. Clean sealing surfaces. Adjust linkage correctly. See Pushbutton Set-Stop Counter Service Manual. Disassemble and remove obstruction. Inspect valve internals for damage. See Troubleshooting Section in Pushbutton Set-Stop Counter Service Manual. Check orifice in upper piston of P-2 or PG-2 Valve (pressure system only). Clean strainer. Replace if necessary. Repair or replace. Disassemble and inspect for foreign particles and/or defects. Repair. Disassemble and remove obstruction. Inspect meter internals for damage. Inspect pump for mechanical or electrical defects. Replace if necessary. Supply product. Normal - product flow automatically is restricted during air elimination. Replace with pump of sufficient capacity. Check pump. Adjust linkage correctly. Replace seal. Disassemble valve and remove foreign matter. Check seal for damage. Replace. See Veeder Root Service Manual. Issue/Rev. 0.5 (6/11)