Download Technical Support Training Document

Transcript
Test Type
Error Codes
Description of Test
POSSIBLE CAUSE
Leakage
108063 - 108066
Checks leakage between ISEREF and WKG1-3 and Heater Low
Leakage
108067
Checks for null leakage on WKG1 channel without generating a stimulus
leakage current on other pins.
Leakage
108068 - 108069
Checks leakage between WKG1 and other pins.
Leakage
108070
Checks for null leakage on WKG2 channel without generating a stimulus
leakage current on other pins.
Leakage
108071
Checks leakage between WKG2 and other pins.
Leakage
108072
Checks for null leakage on WKG3 channel without generating a stimulus
leakage current on other pins.
Leakage
108073
Checks leakage between WKG3 and other pins.
Leakage
108074
Checks leakage from MF1 (multifunction 1) pin to other MF pins,
reference pins, heater hi and heater low.
Leakage
108075
Checks leakage from MF2 (multifunction 2) pin to other MF pins,
reference pins, heater hi and heater low.
Leakage
108076
Checks leakage from MF3 (multifunction 3) pin to other MF pins,
reference pins, heater hi and heater low.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Extremely high humidity
Contamination on WKG1 channel on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Extremely high humidity
Contamination on WKG2 channel on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Extremely high humidity
Contamination on WKG3 channel on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Contaminated Edge Connector
Extremely high humidity
Contamination between channels on main circuit board
Latent circuit failure
Diametrics Medical, Inc.
Pg.
(Note: This is a controlled document. All changes must be authorized by DMI and revision controlled. This document is not intended for customer use.)
35