Download Technical Support Training Document
Transcript
Test Type Error Codes Description of Test POSSIBLE CAUSE Leakage 108063 - 108066 Checks leakage between ISEREF and WKG1-3 and Heater Low Leakage 108067 Checks for null leakage on WKG1 channel without generating a stimulus leakage current on other pins. Leakage 108068 - 108069 Checks leakage between WKG1 and other pins. Leakage 108070 Checks for null leakage on WKG2 channel without generating a stimulus leakage current on other pins. Leakage 108071 Checks leakage between WKG2 and other pins. Leakage 108072 Checks for null leakage on WKG3 channel without generating a stimulus leakage current on other pins. Leakage 108073 Checks leakage between WKG3 and other pins. Leakage 108074 Checks leakage from MF1 (multifunction 1) pin to other MF pins, reference pins, heater hi and heater low. Leakage 108075 Checks leakage from MF2 (multifunction 2) pin to other MF pins, reference pins, heater hi and heater low. Leakage 108076 Checks leakage from MF3 (multifunction 3) pin to other MF pins, reference pins, heater hi and heater low. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Extremely high humidity Contamination on WKG1 channel on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Extremely high humidity Contamination on WKG2 channel on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Extremely high humidity Contamination on WKG3 channel on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Contaminated Edge Connector Extremely high humidity Contamination between channels on main circuit board Latent circuit failure Diametrics Medical, Inc. Pg. (Note: This is a controlled document. All changes must be authorized by DMI and revision controlled. This document is not intended for customer use.) 35