Figure 18
Figure 19
Figure 20 - Shims
Figure 21 – Anchor Bolts
3.
Refer to Bay Layout (Figure 4) to ensure that the column is still in the
proper position. Using a rotary hammer drill with a 3/4” masonry drill bit
and using the tower baseplate as a template, drill holes through the
concrete floor on the high side column (In case longer anchors are
required, supplied anchors can be hammered through concrete). Make
sure that the 3/4” masonry drill is in good condition (Figure 21).
4.
Carefully clean out drilling dust from the anchor holes. Hammer in the
anchor bolts until they make contact with the baseplate (Figure 21). Hand
tighten all anchor bolts.
5.
Check the distance from the top of the anchor to the floor. If this
dimension exceeds 2¼” due to floor slope, DO NOT use the supplied
anchors. Longer anchor must be used (see #1 above).
21 of 36