No. 8 Part to be exchanged Attachment/ detachment of pipe fixing rubber Work procedure REQUIREMENT Remarks 1) Put on gloves during working; otherwise an injury may be caused by parts, etc. <Disassembling> 1) Hold the both ends (longitudinal direction) of the rubber lightly, and then make a margin between SUS band and fixing rubber. Compress rubber and make margin. 2) 2) Pushing in the claw side of SUS band with fingers, the claw comes off from the square hole. Push in the band toward arrow mark. <Assembly> Align direction of the slits, and then attach to each pipe. 1) The fixing rubber is a segmentation system due to freedom degree of combination. Therefore, for assembly, it is recommended to fit both pipes including the fixing rubber after passing the rubber through the pipes separately. In this time, check both slit direct the same direction. 1) 1) 2) Align the claw side of SUS band to slit side of the rubber for assembly. (Assembly in reverse direction is also available, but the work performance decreases.) 3) Attach the band so that a clearance does not generate between SUS band and fixing rubber. Especially pay attention not to generate a clearance at part of the hair pin side of the band. 4) Fit the root of claw to the rubber lightly, push R part at square hole side toward the arrow mark, and then hook the claw to the square hole. (If it is not hooked, recheck 3) there is no clearance between band and rubber.) Matching the claws, slide them. Align the claw to slit side of the rubber. 2) Slide it. Push the band against rubber without clearance. 3) Slide the square hole side toward arrow mark. 4) Push claw side against the rubber. 257