Download System Integrator`s Guide
Transcript
LonWorks System Integrator Guide for the Intelli-Fin Boiler Interface Controller Version LOCH SIG-01 Page 3 TABLE OF CONTENTS Who should read the System Integrators Guide?.......................................................................................................................... 3 Abbreviations used in this document............................................................................................................................................ 4 Trademarks ................................................................................................................................................................................... 4 References .................................................................................................................................................................................... 4 Benefits of System Integration ..................................................................................................................................................... 5 LonWorks overview ..................................................................................................................................................................... 7 BIC details .................................................................................................................................................................................... 8 One unit .................................................................................................................................................................................... 8 Multiple units for increased capacity ...................................................................................................................................... 12 Intended uses .......................................................................................................................................................................... 13 Network Variables Available to the System Integrator .......................................................................................................... 14 Node Object (nviRequest, nvoStatus, and nciConfigSr)................................................................................................. 14 Data sharing between units and sequencer (nvoSeqShare, nviSeqShare, nvoModBoilrShare, nviModBoilrShare)....... 16 Operating Mode (nvoData.Mode)................................................................................................................................... 17 Time in a given mode (nvoData.ModeTimer) ................................................................................................................ 19 Number of heat stages requested to be turned on (nvoData.HeatStages)........................................................................ 19 Variable frequency drive position (nvoData.VFDPos) ................................................................................................... 19 Bypass valve position (nvoDataBypassPos) ................................................................................................................... 19 Boiler Run Time (nvoIO.BlrTotRtHr) ............................................................................................................................ 20 Temperature reports........................................................................................................................................................ 21 On / Off information ....................................................................................................................................................... 22 Occupancy status ............................................................................................................................................................ 23 Configuration Parameters setting temperatures .............................................................................................................. 24 Control Point Calculation ....................................................................................................................................................... 25 BIC and CD Factory Set Configuration.................................................................................................................................. 26 What is LNS?.............................................................................................................................................................................. 27 What is LonMaker? .................................................................................................................................................................... 28 What is needed for system integration? ...................................................................................................................................... 29 Step by step integration............................................................................................................................................................... 29 Ordering and Unit Installation Task ....................................................................................................................................... 30 System Integrator Task - Add BIC system to building network (Offnet) .............................................................................. 30 Install the resource files into the appropriate directories ................................................................................................ 30 Register the resource files in the resource catalog .......................................................................................................... 31 Back up any existing network before making any major changes to an existing network.............................................. 31 Add BICs (sequencer and units) and dummy CDs to either a new or existing LNS network......................................... 32 Configure the LNS data base so that the BIC uses a device specific resource file ......................................................... 36 Add boiler function blocks (objects) for the sequencer and each of the units to the network......................................... 39 Bind the Sequencer BIC to the Unit BICs for normal sequencer operation.................................................................... 41 Order replacement CDs................................................................................................................................................... 44 Make custom graphical user interfaces to display system status .................................................................................... 46 Reprogramming CDs Task .................................................................................................................................................... 46 Prepare to connect LonWorks Network wire to the BIC System Task................................................................................... 46 System Integrator Task – Final Integration (OnNet) .............................................................................................................. 46 Shut down the boiler system ........................................................................................................................................... 46 Remove the CDs from the system................................................................................................................................... 46 Connect the BIC System to the building LonWorks Network........................................................................................ 46 Commission the BICs ..................................................................................................................................................... 47 Install the replacement CDs ............................................................................................................................................ 52 Return the boiler system to operation ............................................................................................................................. 52 Test any network functions............................................................................................................................................. 52 Appendix A – Network variable description .............................................................................................................................. 53 Who should read the System Integrators Guide? The system integrators guide is designed for use by anyone that could benefit by connecting the Intelli-Fin unit to a LonWorks building automation system. Specifically consulting engineers, and building owners will find the Benefits of System Integration section useful. LonMark system integrators will find the detailed information required to integrate the