Download Service - Expert-CM
Transcript
11 - AIR-BREAK & BOILERS For the BRIO 3 model there are three base versions: 1) Espresso version with a pressure boiler controlled by the air-break. 2) Instant version, fitted with the same pressure boiler of the espresso version, also controlled by the air break. 3) Fresh- brew version, fitted with only the special open-top instant boiler, developed from the boiler of the KORO with incorporated air-break (see specific service manual). The espresso boiler is the same used for the Astro and Kikko models, therefore with the same well known and established characteristics and reliability. For technical information see the “Service manual” of Boiler functional units 2 1 3 4 LOCATION OF PRESSURE BOILER DETAIL OF BOILER ASSEMBLY SONDA NTC TERMOSTATO NOTE: The pressure boiler is fitted with a safety system against overheating CALDAIA 1) Dry operation protection. The internal temperature control is by means of an NTC type electronic probe fitted with an internal 12K ohm (+/- 4 ohm) resistance at a temperature of 25° C. ( 3 ) In the event of failure to the control system, the software detects such condition and stops the heating, indicating on the display the boiler malfunction condition; in the event of electronic failure to the actuation system or software failure, the bipolar thermostat (1) is triggered, disconnecting the power supply to the heating elements (4). Boiler temperature °C Value in ohm Allowed tolerance 0 25 50 85 90 100 35875 12000 2900 1475 1260 963 +/-7 ohm +/- 4 ohm ,, ,, ,, ,, NECTA SPA TECHNICAL MANUAL “ Brio 3 “ This document was produced by MARK AC for the exclusive use of the technical personnel in the after-sales service. . No part of this document may be divulged to a third party or reproduced partially or entirely without the prior permission of NW GLOBAL VENDING . All rights reserved. New Brio 15/05/2006 page 23 / 43