11 - AIR-BREAK & BOILERS
For the BRIO 3 model there are three base versions:
1) Espresso version with a pressure boiler controlled by the air-break.
2) Instant version, fitted with the same pressure boiler of the espresso version, also controlled by the air
break.
3) Fresh- brew version, fitted with only the special open-top instant boiler, developed from the boiler of the
KORO with incorporated air-break (see specific service manual).
The espresso boiler is the same used for the Astro and Kikko models, therefore with the same well known
and established characteristics and reliability.
For technical information see the “Service manual” of Boiler functional units
2
1
3
4
LOCATION OF PRESSURE BOILER
DETAIL OF BOILER ASSEMBLY
SONDA NTC
TERMOSTATO
NOTE: The pressure boiler is fitted with a safety system against
overheating
CALDAIA
1) Dry operation protection.
The internal temperature control is by means of an NTC type electronic probe fitted with an internal 12K
ohm (+/- 4 ohm) resistance at a temperature of 25° C. ( 3 )
In the event of failure to the control system, the software detects such condition and stops the heating,
indicating on the display the boiler malfunction condition; in the event of electronic failure to the actuation
system or software failure, the bipolar thermostat (1) is triggered, disconnecting the power supply to the
heating elements (4).
Boiler temperature °C
Value in ohm
Allowed tolerance
0
25
50
85
90
100
35875
12000
2900
1475
1260
963
+/-7 ohm