Download Technical Publication
Transcript
GE MEDICAL SYSTEMS DIRECTION 2300164-100, REVISION 7 8-5-2-4 NOTE: VIVID™ 3 PRO/VIVID™ 3 SERVICE MANUAL Back End Processor Installation Procedure When performing this procedure, handle boards carefully and take the following precautionary measures: CAUTION: DO NOT TOUCH ANY BOARDS WITH INTEGRATED CIRCUITS PRIOR TO TAKING THE NECESSARY ESD PRECAUTIONS: 1.ALWAYS CONNECT YOURSELF, VIA AN ARM-WRIST STRAP, TO THE ADVISED ESD CONNECTION POINT LOCATED ON THE REAR OF THE SCANNER (TO THE RIGHT OF THE POWER CONNECTOR). 2.FOLLOW GENERAL GUIDELINES FOR HANDLING OF ELECTROSTATIC SENSITIVE EQUIPMENT. NOTE: Care should also be taken to install the boards in the correct slots - refer to Figure 8-50 on page 8-56 and Figure 8-51 on page 8-57, as applicable. 1) Install the MO Driver into the new BEP, as described in the MO Drive Installation Procedure on page 8 - 81, if applicable. 2) Remove the Octopus Card Holder as described in the BEP2 - Octopus Card Holder Removal Procedure on page 8 - 68. 3) Install the SCSI Board, as described in the SCSI Board Installation Procedure on page 8 - 73, if applicable. 4) Install the ECG Module, as described in the BEP2 - ECG Module Installation Procedure on page 8 - 86. 5) Install the PC VIC Assembly, as described in the PC-VIC Installation Procedure on page 8 - 89. 6) Install the Plug and Scan Battery (if applicable), as described in the Plug & Scan Battery Installation Procedure on page 8 - 71. 7) Install the Plug and Scan Board (if applicable), as described in the Plug & Scan Board Installation Procedure on page 8 - 69. 8) Install the PC2IP Board, as described in the PC2IP Board Installation Procedure on page 8 - 75. 9.) Install the Frame Grabber Board (RFI systems only), as described in the Frame Grabber Board Installation Procedure on page 8 - 76. 10) Install the Keyboard Control Card, as described in the Keyboard Control Board Installation Procedure on page 8 - 77. 11) Install the Octopus Card Holder as described in the BEP2 - Octopus Card Holder Installation Procedure on page 8 - 68. 12.)Carefully return the new BEP to the original position on the machine chassis. Note: When replacing a BEP, the HASP key must be moved to the new BEP. Ensure that the HASP key is connected to the parallel port. Make sure that the nominal voltage and range is set correctly in the Technical Support Tab under System Configuration. (This must be done by an authorized GE representative). Software version 2.3 or above must be re-installed - see the Software Installation/Upgrade Procedure on page 8 - 121. Slide the BEP slightly outwards and proceed to reconnect all the cables at the rear of the BEP as described in the following steps (refer to Figure 8-55 on page 8-61). Make sure that the HASP key (option plug) is connected to the correct connector (parallel port). 8-60 Section 8-3 - Control Console Components Replacement
Related documents
Artisan Technology Group is your source for quality new and
GE Vivid 3 Pro / Vivid 3 Manual 3
chapter 4
FB091565 Revision 1 GE Medical Systems Vivid 5 Service Manual
Technical Publication Direction 2300000 Revision 0 GE Medical
LOGIQ Book XP/XP PRO/XP Vet Service Manual
Endoscopic Units
CV-180 EVIS EXERA II Video System Center
Technical Publications Vivid 3 User`s Guide
GE Vivid i user manual
Omnesys Technologies Private Limited. NEST An ECO system for
chapter 2