Download DCB_DCFCB_DCFCTB Controller Manual
Transcript
Specifications Charging System and Recommended Batteries Chargers (one per battery) Charger Output Voltage Charger Output Current 13.50 VDC at 100 mA 4 Amps maximum Recommended Batteries (user supplied) Refer to Federal Signal Website (http://www.alertnotification.com/) for current recommended batteries. Use of batteries other than those specified may degrade the operation of this product and void the warranty. Environmental Environmental Operating Temperature -30 to +65C (with batteries maintained at -18C minimum) Dimensions Dimensions (H x W x D) Control Cabinet (NEMA 4) Battery Box (Vented NEMA 4) Overall (including channel) 23.5 inches x 19 inches x 11.19 inches 597 mm x 483 mm x 284 mm 18 inches x 28 inches x 15.19 inches 457 mm x 711 mm x 386 mm 62.5 inches x 23.5 inches x 16.94 inches 1588 mm x 597 mm x 430 mm 364 pounds (165 kg.) 300 pounds (136 kg.) Total Weight (including batteries) Shipping Weight (excluding batteries) Control Board Specifications Input Power Requirements AC Power AC supply voltage (switchable) Current draw Backup Battery DC Voltage Current Draw with AC present without AC (back up mode) with 2-way Radio 120 VAC +/- 10%, 50-60 Hz or 220 VAC +/- 10%, 50-60 Hz 0.2A max. 15 – 75 VDC none 150 mA Standby (without 2-way radio) (Transceiver is 350 mA in Standby, 8 A transmit typical–refer to radio specifications for the actual radio model in use.) DCB, DCFCB and DCFCTB Models 9