Download DCB_DCFCB_DCFCTB Controller Manual

Transcript
Specifications
Charging System and Recommended Batteries
Chargers (one per battery)
Charger Output Voltage
Charger Output Current
13.50 VDC at 100 mA
4 Amps maximum
Recommended Batteries (user supplied)
Refer to Federal Signal Website (http://www.alertnotification.com/) for current
recommended batteries. Use of batteries other than those specified may degrade the
operation of this product and void the warranty.
Environmental
Environmental
Operating Temperature
-30 to +65C
(with batteries maintained at -18C minimum)
Dimensions
Dimensions (H x W x D)
Control Cabinet
(NEMA 4)
Battery Box
(Vented NEMA 4)
Overall (including channel)
23.5 inches x 19 inches x 11.19 inches
597 mm x 483 mm x 284 mm
18 inches x 28 inches x 15.19 inches
457 mm x 711 mm x 386 mm
62.5 inches x 23.5 inches x
16.94 inches
1588 mm x 597 mm x 430 mm
364 pounds (165 kg.)
300 pounds (136 kg.)
Total Weight (including batteries)
Shipping Weight (excluding
batteries)
Control Board Specifications
Input Power Requirements
AC Power
AC supply voltage (switchable)
Current draw
Backup Battery
DC Voltage
Current Draw
with AC present
without AC (back up
mode)
with 2-way Radio
120 VAC +/- 10%, 50-60 Hz or
220 VAC +/- 10%, 50-60 Hz
0.2A max.
15 – 75 VDC
none
150 mA Standby (without 2-way radio)
(Transceiver is 350 mA in Standby,
8 A transmit typical–refer to radio specifications for the
actual radio model in use.)
DCB, DCFCB and DCFCTB Models