Remote Interface Setup Pressing remote… calls the REMOTE SETUP screen which permits RS232/GPIB choice and selection of address and Baud rate. Full details are given in the Remote Operation section. Reference Clock In/Out Setting The function of the rear panel REF CLOCK IN/OUT socket is set on the REF. CLOCK I/O screen, called by pressing the ref. clock i/o soft−key. REF. CLOCK I/O: ♦input ◊output ◊phase lock The default setting is for the socket to be set to input, i.e. an input for an external 10MHz reference clock. When set to input the system is automatically switched over to the external reference when an adequate signal level (TTL/CMOS threshold) is detected at REF CLOCK IN/OUT but will continue to run from the internal clock in the absence of such a signal. With the clock set to output a buffered version of the internal 10MHz clock is made available at the socket. With phase lock selected the socket can be set to be a master or slave when used for synchronising (phase−locking) multiple generators. See Synchronising Generators section for full details. Cursor/Marker Output Pressing the cursor/marker… soft−key calls the CURSOR/MARKER OUTPUT screen. CURSOR/MARKER OUTPUT amplitude: 2V ◊polarity: negative ◊cursor width: 1 The cursor/marker signal is output from the rear panel CURSOR/MARKER OUT socket. It is used as a marker in sweep mode or as a cursor in arbitrary waveform mode. It can be used to modulate the Z−axis of an oscilloscope or be displayed on a second ‘scope channel. With amplitude selected the cursor/marker level can be set between 2 and 14V in 2V steps. With polarity selected the polarity can be set positive or negative. With polarity set to positive the cursor/marker is a positive−going pulse from the 0V baseline; with polarity set to negative the cursor/marker is a negative−going pulse from the 2 − 14V set amplitude level, i.e. negative gives an inverted signal. When used as a sweep marker (i.e. Sweep mode selected) the width is determined by the time spent at the marker frequency, see Sweep Marker in the Sweep Operation section for details. When used as a cursor during arbitrary waveform editing (i.e. edit waveform selected on the MODIFY screen) the width can be adjusted by repeated presses of the cursor width soft−key or by using the rotary control. The width is adjustable so that the cursor can still be made visible even with long arbitrary waveforms. The width is always an odd number of waveform points increasing in steps of 2 points from 1 to 3, 5, 7, etc. A width setting of 1 corresponds to 1 waveform point, width 2 is 3 points, width 3 is 5 points and so on up to width 30 which is 59 points. 68