Download Dynamic Perception MX3 Motion Controller
Transcript
You can temporarily acknowledge an alarm by pressing [Enter], and the alarm will go away for fifteen seconds. 8.1. Input Voltage Alarm A low input voltage can indicate that a battery has been discharged more than it should be and you may soon lose power. As the MX3 takes a wide variety of voltage inputs, you can modify the threshold of this warning, or you can disable this warning entirely if it presents issues for you. This alarm is automatically disabled when running on USB power alone. To set the voltage alarm threshold or disable the voltage warning, follow these menu actions: 1. [Enter] to enter the Main System Menu 2. [Up] or [Down] until Settings is selected 3. [Enter] to enter Settings menu 4. [Up] or [Down] until Sensors is selected 5. [Enter] to enter sensors menu 6. [Up] or [Down] until the desired parameter (Voltage Warn or Voltage Thresh) is selected 7. [Enter] to edit the parameter 8. [Up] or [Down] to modify the value 9. [Enter] or [Right] to save the new value 8.2. Motor Current Alarm If the motors draw more current than the device can support, damage to the MX3 can happen. Usually, too much current draw indicates that one or more motors require more current than the MX3 can support, or that a motor has stalled and severe damage to the motor or the MX3 may occur. When a motor current alarm is triggered, all motor movement will be immediately stopped and a warning screen will be presented for fifteen seconds. The motor current alarm cannot be disabled. Page 31 of 50 Copyright © 2014 Dynamic Perception LLC dynamicperception.com All Contents licensed under the Creative Commons Attribution ShareAlike 3.0 License