Download RFcap: A software a

Transcript
*Manuscript DO NOT INCLUDE ANY AUTHOR NAMES OR CONTACT DETAILS IN THIS FILE
Click here to download Manuscript DO NOT INCLUDE ANY AUTHOR NAMES OR CONTACT DETAILS IN THIS FILE: Manuscript_11
1
1
2
2
3
43
5
64
7
8
95
10
11 6
12
13
14 7
15
16 8
17
18
9
19
20
2110
22
2311
24
25
2612
27
2813
29
30
3114
32
3315
34
35
3616
37
3817
39
40
18
41
42
4319
44
4520
46
47
4821
49
5022
51
52
5323
54
5524
56
57
25
58
59
6026
61
62
63
64
65
Introduction
The ability to display and analyze the output of the speech processor which encodes the stimuli to
be delivered by a cochlear implant (CI) can be extremely helpful and even essential in many
instances, both in research as well as clinical settings. For example, when developing new speech
coding strategies, the output of the new algorithms need to be examined systematically and
thoroughly. This is not difficult with simple inputs, but it becomes cumbersome when complex
inputs such as real speech tokens are used. Displaying the complex signal output makes it possible
to examine this output for patterns that may otherwise not be easily observed when using simple
input signals. Another example, in a clinical environment, is to examine the output of a speech
processor for diagnosing hardware problems such as defective microphones or accessories.
With the present generation of commercial cochlear implant systems approved for clinical use,
stimulus parameters are transmitted via radio frequency (RF) coded signals transcutaneously to the
cochlear implant. By capturing and decoding these RF coded signals, it is possible to examine the
output of the entire signal processing chain.
Capturing these RF coded signals requires appropriate custom hardware as well as software.
Previously, this was possible for the Nucleus family of cochlear implants using sCILab (Lai et al.
2003), a 16-bit Borland Pascal application which communicated with standard clinical hardware, in
particular with the Nucleus DPI-IF4 (Dual Processor Interface and Nucleus IF4 interface card) and
PCI-IF5 (Processor Control Interface and Nucleus IF5 interface card) hardware combinations.
However, these clinical hardware combinations have since been superseded, and the subsequent
hardware combination of PCI with the Nucleus IF6 interface card is not compatible with sCILab.
Furthermore, the latest clinical hardware with a USB programming Pod does not have any decoding
or storage capability.
The PCI-IF6 combination, while no longer the latest clinical hardware for the Nucleus CI system,
represents the most recent and still available hardware configuration able to continuously decode
and store the RF signals. The software functionality to communicate with the hardware and thus
1