Download RFcap: A software a
Transcript
*Manuscript DO NOT INCLUDE ANY AUTHOR NAMES OR CONTACT DETAILS IN THIS FILE Click here to download Manuscript DO NOT INCLUDE ANY AUTHOR NAMES OR CONTACT DETAILS IN THIS FILE: Manuscript_11 1 1 2 2 3 43 5 64 7 8 95 10 11 6 12 13 14 7 15 16 8 17 18 9 19 20 2110 22 2311 24 25 2612 27 2813 29 30 3114 32 3315 34 35 3616 37 3817 39 40 18 41 42 4319 44 4520 46 47 4821 49 5022 51 52 5323 54 5524 56 57 25 58 59 6026 61 62 63 64 65 Introduction The ability to display and analyze the output of the speech processor which encodes the stimuli to be delivered by a cochlear implant (CI) can be extremely helpful and even essential in many instances, both in research as well as clinical settings. For example, when developing new speech coding strategies, the output of the new algorithms need to be examined systematically and thoroughly. This is not difficult with simple inputs, but it becomes cumbersome when complex inputs such as real speech tokens are used. Displaying the complex signal output makes it possible to examine this output for patterns that may otherwise not be easily observed when using simple input signals. Another example, in a clinical environment, is to examine the output of a speech processor for diagnosing hardware problems such as defective microphones or accessories. With the present generation of commercial cochlear implant systems approved for clinical use, stimulus parameters are transmitted via radio frequency (RF) coded signals transcutaneously to the cochlear implant. By capturing and decoding these RF coded signals, it is possible to examine the output of the entire signal processing chain. Capturing these RF coded signals requires appropriate custom hardware as well as software. Previously, this was possible for the Nucleus family of cochlear implants using sCILab (Lai et al. 2003), a 16-bit Borland Pascal application which communicated with standard clinical hardware, in particular with the Nucleus DPI-IF4 (Dual Processor Interface and Nucleus IF4 interface card) and PCI-IF5 (Processor Control Interface and Nucleus IF5 interface card) hardware combinations. However, these clinical hardware combinations have since been superseded, and the subsequent hardware combination of PCI with the Nucleus IF6 interface card is not compatible with sCILab. Furthermore, the latest clinical hardware with a USB programming Pod does not have any decoding or storage capability. The PCI-IF6 combination, while no longer the latest clinical hardware for the Nucleus CI system, represents the most recent and still available hardware configuration able to continuously decode and store the RF signals. The software functionality to communicate with the hardware and thus 1