Download Claire Lestrade - Parent Directory
Transcript
multiconductor structure. The option ‘Save’ in the file menu allows one to save the circuit currently being worked on in the ‘Example’ format. This command can only be used after having either created a new file or opened an already-existing file. The user does not need to save the circuit displayed on the drawing area except to keep it for future use: once the circuit is saved, it may be opened and modified any time using the option ‘Open’ in the file menu. The option ‘Mesh’ in the file menu enables the user to create the mesh files for all the conductors of the circuit. However, the number of basis functions per side has to be defined first in the menu ‘Edit-Quality’ (cf. Section 3.4.2). Once the quality of the simulation has been defined, the user may start the mesh creation using the ‘Mesh’ option in the file menu. An information window will warn the user when the mesh creation is done. There are three types of mesh files: strip.mesh, rect.mesh, and circle.mesh, depending on the shape of the conductor. One file will be created for each conductor involved in the structure. For example, if the structure includes two rectangular conductors and one circular conductor, the files created will be ‘rect1.mesh,’ ‘rect2.mesh,’ and ‘circle3.mesh.’ The option ‘Solve’ in the file menu allows the user to run the simulation on the circuit. It will use as an input the circuit displayed in the drawing area and the mesh files created by the option ‘Mesh.’ Consequently, the mesh creation should be done before running the simulation with ‘Solve.’ Once the option ‘Solve’ has been chosen, the program XRLGC will start to compute the R, L, G, and C parameters of the structure considered. As soon as the RLGC simulation is done, a new custom dialog will appear on the screen. This dialog allows the user to specify the window used for the potential simulation. The user will also decide which conductor should be excited, and the number of points that should be used in the x and y directions. Having typed in the corresponding information, the user may click on the button ‘OK’ of the potential simulation dialog. This allows the program XRLGC to complete the full simulation. However, if instead the button ‘Cancel’ is chosen, then the potential distribution will not be computed. Once the simulation is done, an information window will warn the user that the circuit has been solved. Charge and potential distribution will then be available in the files ‘Example.Q2D’ and ‘Example.V2D.’ The RLGC matrix will be available in the file ‘Example.out,’ but it may also be displayed using the command ‘View-RLGC’ on the menu. The option ‘Exit’ in the file menu allows the user to quit the program. The user should save any modification in the circuit using the option ‘File-Save’ before using this command. 20