Now suppose that the interrogation is repeated at the second segment when Y=2000. The value of
_AV at this point is 7000, _CS equals 1, _VPX=5000 and _VPY=0.
Example - Linear Move
Make a coordinated linear move in the ZW plane. Move to coordinates 40000,30000 counts at a vector
speed of 100000 counts/sec and vector acceleration of 1000000 counts/sec2.
Instruction
Interpretation
#TEST
Label
LM ZW
Specify axes for linear interpolation
LI,,40000,30000
Specify ZW distances
LE
Specify end move
VS 100000
Specify vector speed
VA 1000000
Specify vector acceleration
VD 1000000
Specify vector deceleration
BGS
Begin sequence
AMS
After motion sequence ends
EN
End program
Note that the above program specifies the vector speed, VS, and not the actual axis speeds VZ and VW.
The axis speeds are determined by the DMC 1300 from:
VS = VZ 2 + VW 2
The resulting profile is shown in Figure 6.2.
DMC 1300