Download GSFL53 - DCbox

Transcript
SYSTEM (SYS) SETTING GROUP PROCEDURE
D
While Pass Code is correct, Press ENT for 3 sec can select SYS Setting Group.
Display
Default
Descriptions
Name
K Factor Decimal 1. Press ENT to enter this parameter, press↑or↓can modify
the K Factor decimal point.
Point Setting 2. Press ENT for 3 SEC to save the parameter and go to the
(dPk)
next parameter
1. Press ENT to enter this parameter, press↑or↓can modify
K Factor
the K Factor range
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
(kF)
next parameter
Flow Unit 1. Press ENT to enter this parameter, press↑or↓can modify
the flow unit: Leter, Gal,M3, CC
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
(unit)
next parameter
Total Time 1. Press ENT to enter this parameter, press↑or↓can modify
time unit: sec, min, hour, day, month
Unit Setting 2. the
Press ENT for 3 SEC to save the parameter and go to the
(C.tiME)
next parameter
1.
Rate Decimal Press ENT to enter this parameter, press↑or↓can modify
the rate decimal point.
Point Setting 2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
(dP)
Sampling Time 1. Press ENT to enter this parameter, press↑or↓can modify
the sampling time.
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
(tbASE)
next parameter
Display Average 1. Press ENT to enter this parameter, press↑or↓can modify
the display average. (1~99)
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
(AvG)
next parameter
Display Low Cut 1. Press ENT to enter this parameter, Press ↑or↓can modify
the value, range: 0~99
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
(LCUt)
next parameter
ALARM (roP) SETTING GROUP PROCEDURE
D
While Pass Code is correct, Press ENT for 3 sec can select ROP Setting Group.
Display
Default
Name
Alarm 1 Setpoint Example:
1. The alarm is on while the display is 50.0, the value must be
Setting
set for 50.0
(Al1)
Press ENT to enter this parameter,
Press ENT again to move the digit.
Alarm 2 Setpoint
Press ↑or↓can modify the value, range: 0~9999
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
(Al2)
Description: Hi: Alarm on while the display higher than setpoint.
AL1 Action
Lo: Alarm on while the display lower than setpoint.
Setting
Range: Hi (≧ Alarm setpoint ), Lo (< Alarm setpoint )
(ACt1)
1. Press ENT to enter this parameter, press↑or↓can modify
AL2 Action
the value.
Setting
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
(ACt2)
Description:
AL1 Hysteresis 1. If the Alarm actions is Hi, the display must lower than
(Setpoint-HYS) value, the Alarm will be off.
Setting
2. If the Alarm actions is Lo, the display must lower than
(HYS1)
(Setpoint+HYS) value, the Alarm will be off.
3. Press ENT to enter this parameter.
AL2 Hysteresis
Press ENT again to movethe digit.
Setting
Press ↑or↓can modify the value, range: 0~99
4. Press ENT for 3 SEC to save the parameter and go to the
(HSY2)
next parameter
Description:
1. If the value is 5, while the display reaches the Alarm setpoint,
Alarm will be on after 5 sec.
2. Press ENT to enter this parameter.
Press ENT again to movethe digit.
AL2 Run Delay
Press ↑or↓can modify the value, range: 0~99(sec)
Setting
3. Press ENT for 3 SEC to save the parameter and go to the
(dEL2)
next parameter
AL1 Run Delay
Setting
(dEL1)
1. Press ENT to enter this parameter, press ↑or↓can modify the
Key Lock Setting
value, range: no(unlock),YES(lock)
(LoCk)
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
1. Press ENT to enter this parameter, press ↑or↓can modify
Pass Code Setting the value, range: 0~9999
(CodE)
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
Example:
1. The display is 4.0 to output 4mA, this value must be 4.0.
A/O Low
Press ENT to enter this parameter,
Scale Setting
Press ENT again to move the digit.
Press ↑or↓can modify the value, range: 0~9999
(AnLo)
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
Example:
1. The display is 100.0 to output 20mA, this value must be 100.0.
A/O Hi
Press ENT to enter this parameter,
Press ENT again to move the digit.
Scale Setting
Press ↑or↓can modify the value, range: 0~9999
(AnHi)
2. Press ENT for 3 SEC to save the parameter and go to the
next parameter
Descriptions
AL Start Band
Setting
( Sb)
Description:
1. If the value is 5, if the display is under 5, Alarm will not be ON.
2. If this value is5, while the display reaches the Alarm start band
range, the Alarm will be on after Sdt time.
3. Press ENT to enter this parameter.
Press ENT again to movethe digit.
Press ↑or↓can modify the value, range: 0~99(sec)
3. Press ENT for 3 SEC to save the parameter and go to the
next parameter
※This function can prevent the wrong action by starting current
AL Start Delay
Time Setting
( Sdt)
Description:
1. While the dispaly reach the Alarm start band range, the Alarm
will be on after this time.
(P.S. :This parameter must be use with Sb together)
3. Press ENT to enter this parameter.
Press ENT again to movethe digit.
Press ↑or↓can modify the value, range: 0~99(sec)
3. Press ENT for 3 SEC to save the parameter and go to the
next parameter