Download GSFL53 - DCbox
Transcript
SYSTEM (SYS) SETTING GROUP PROCEDURE D While Pass Code is correct, Press ENT for 3 sec can select SYS Setting Group. Display Default Descriptions Name K Factor Decimal 1. Press ENT to enter this parameter, press↑or↓can modify the K Factor decimal point. Point Setting 2. Press ENT for 3 SEC to save the parameter and go to the (dPk) next parameter 1. Press ENT to enter this parameter, press↑or↓can modify K Factor the K Factor range Setting 2. Press ENT for 3 SEC to save the parameter and go to the (kF) next parameter Flow Unit 1. Press ENT to enter this parameter, press↑or↓can modify the flow unit: Leter, Gal,M3, CC Setting 2. Press ENT for 3 SEC to save the parameter and go to the (unit) next parameter Total Time 1. Press ENT to enter this parameter, press↑or↓can modify time unit: sec, min, hour, day, month Unit Setting 2. the Press ENT for 3 SEC to save the parameter and go to the (C.tiME) next parameter 1. Rate Decimal Press ENT to enter this parameter, press↑or↓can modify the rate decimal point. Point Setting 2. Press ENT for 3 SEC to save the parameter and go to the next parameter (dP) Sampling Time 1. Press ENT to enter this parameter, press↑or↓can modify the sampling time. Setting 2. Press ENT for 3 SEC to save the parameter and go to the (tbASE) next parameter Display Average 1. Press ENT to enter this parameter, press↑or↓can modify the display average. (1~99) Setting 2. Press ENT for 3 SEC to save the parameter and go to the (AvG) next parameter Display Low Cut 1. Press ENT to enter this parameter, Press ↑or↓can modify the value, range: 0~99 Setting 2. Press ENT for 3 SEC to save the parameter and go to the (LCUt) next parameter ALARM (roP) SETTING GROUP PROCEDURE D While Pass Code is correct, Press ENT for 3 sec can select ROP Setting Group. Display Default Name Alarm 1 Setpoint Example: 1. The alarm is on while the display is 50.0, the value must be Setting set for 50.0 (Al1) Press ENT to enter this parameter, Press ENT again to move the digit. Alarm 2 Setpoint Press ↑or↓can modify the value, range: 0~9999 Setting 2. Press ENT for 3 SEC to save the parameter and go to the next parameter (Al2) Description: Hi: Alarm on while the display higher than setpoint. AL1 Action Lo: Alarm on while the display lower than setpoint. Setting Range: Hi (≧ Alarm setpoint ), Lo (< Alarm setpoint ) (ACt1) 1. Press ENT to enter this parameter, press↑or↓can modify AL2 Action the value. Setting 2. Press ENT for 3 SEC to save the parameter and go to the next parameter (ACt2) Description: AL1 Hysteresis 1. If the Alarm actions is Hi, the display must lower than (Setpoint-HYS) value, the Alarm will be off. Setting 2. If the Alarm actions is Lo, the display must lower than (HYS1) (Setpoint+HYS) value, the Alarm will be off. 3. Press ENT to enter this parameter. AL2 Hysteresis Press ENT again to movethe digit. Setting Press ↑or↓can modify the value, range: 0~99 4. Press ENT for 3 SEC to save the parameter and go to the (HSY2) next parameter Description: 1. If the value is 5, while the display reaches the Alarm setpoint, Alarm will be on after 5 sec. 2. Press ENT to enter this parameter. Press ENT again to movethe digit. AL2 Run Delay Press ↑or↓can modify the value, range: 0~99(sec) Setting 3. Press ENT for 3 SEC to save the parameter and go to the (dEL2) next parameter AL1 Run Delay Setting (dEL1) 1. Press ENT to enter this parameter, press ↑or↓can modify the Key Lock Setting value, range: no(unlock),YES(lock) (LoCk) 2. Press ENT for 3 SEC to save the parameter and go to the next parameter 1. Press ENT to enter this parameter, press ↑or↓can modify Pass Code Setting the value, range: 0~9999 (CodE) 2. Press ENT for 3 SEC to save the parameter and go to the next parameter Example: 1. The display is 4.0 to output 4mA, this value must be 4.0. A/O Low Press ENT to enter this parameter, Scale Setting Press ENT again to move the digit. Press ↑or↓can modify the value, range: 0~9999 (AnLo) 2. Press ENT for 3 SEC to save the parameter and go to the next parameter Example: 1. The display is 100.0 to output 20mA, this value must be 100.0. A/O Hi Press ENT to enter this parameter, Press ENT again to move the digit. Scale Setting Press ↑or↓can modify the value, range: 0~9999 (AnHi) 2. Press ENT for 3 SEC to save the parameter and go to the next parameter Descriptions AL Start Band Setting ( Sb) Description: 1. If the value is 5, if the display is under 5, Alarm will not be ON. 2. If this value is5, while the display reaches the Alarm start band range, the Alarm will be on after Sdt time. 3. Press ENT to enter this parameter. Press ENT again to movethe digit. Press ↑or↓can modify the value, range: 0~99(sec) 3. Press ENT for 3 SEC to save the parameter and go to the next parameter ※This function can prevent the wrong action by starting current AL Start Delay Time Setting ( Sdt) Description: 1. While the dispaly reach the Alarm start band range, the Alarm will be on after this time. (P.S. :This parameter must be use with Sb together) 3. Press ENT to enter this parameter. Press ENT again to movethe digit. Press ↑or↓can modify the value, range: 0~99(sec) 3. Press ENT for 3 SEC to save the parameter and go to the next parameter