Download MS-702 Manual - Clear-Com
Transcript
MAINTENANCE INTRODUCTION This chapter provides maintenance information, including a block diagram and troubleshooting tips. Caution:These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. MS-702 BLOCK DIAGRAM The following is a block diagram of the MS-702: MS-702 Headset Mic Headset Main Pgm XLR4 Mic Limiter Panel Mic Jack XLR4 Program Level Line Length Sidetone Null Headset Limiter Panel Mic Gain Listen A Main Pgm Spkr On/Off Intercom Line A Program Level A Mute Line Length Sidetone Null Alert Tone Level Listen B Main Pgm Intercom Line B Program Level B Main Pgm 3 Main Pgm 2 3 +30VDC IEC Power Inlet Switching Power Supply +30VDC SA Output 2 Main Pgm On/Off Alert Tone Generator Power Control uP Hot Mic / IFB Out Power B 2 Channel B 3 1 XLRs (3) +30VDC +5VDC Intercom A Lines B Option Switches Annc Rly Control To All Switches Front Panel Switches, Buttons, & Indicators Call Alert Tone System Logic RMK Power A 2 Channel A 3 1 XLRs (3) Intercom Line Linking & Termination Link Call Signal Send & Receive A Intercom B Lines Figure 3-6: Block diagram of the MS-702 Clear-Com® MS-702 Two-Channel Main Station Instruction Manual 3-1