• Is it a hard fault, or is it intermittent in nature?
• Do the alarms indicate which end of the link is faulty? Hardware, software or
tributary alarms from an element management system should provide
confirmation of the link-end.
• Check the weather conditions leading up to the occurrence of the fault. Could
the weather (rain, ice, high wind, temperature, and so on) be a factor in the
reported fault.
• If the fault suggests a rain fade or other weather related fade condition and it
matches the prevailing weather conditions, do not take any action until the
weather abates.
• Check to determine if you or another engineer is best placed to attend to the
reported fault. This may be assessed by location, experience, access to spares,
and so on.
• Check to see if the alarms suggest the fault may be with connected equipment
and not the reported equipment, such as a mux, other radio equipment, or
tributary line connections.
• Check the terminal / link history:
• Is it a newly installed link?
• Does the fault history for the link indicate a likely cause?
• Has there been work done on the link in recent times, and if so, what?
• Check that you have with you:
• The appropriate spares.
• The craft tool, the right the software revision to enable the craft tool to
communicate with the equipment, and a connecting cable for craft tool
access.
• Any password and/or IP address required to secure craft tool access to the
equipment.
• Any special test equipment that may be needed.
• Toolkit.
• Key(s) for access to the site, and if necessary, the directions on how to get
there.
Where link alarms and performance monitors do not confirm the source of a fault
condition, such as a dribbling BER reported at some point in the network, always
check the alarms of the connected equipment. Never jump to a conclusion that a
radio link is the problem.