Download Best Practices
Transcript
Best Practices • Is it a hard fault, or is it intermittent in nature? • Do the alarms indicate which end of the link is faulty? Hardware, software or tributary alarms from an element management system should provide confirmation of the link-end. • Check the weather conditions leading up to the occurrence of the fault. Could the weather (rain, ice, high wind, temperature, and so on) be a factor in the reported fault. • If the fault suggests a rain fade or other weather related fade condition and it matches the prevailing weather conditions, do not take any action until the weather abates. • Check to determine if you or another engineer is best placed to attend to the reported fault. This may be assessed by location, experience, access to spares, and so on. • Check to see if the alarms suggest the fault may be with connected equipment and not the reported equipment, such as a mux, other radio equipment, or tributary line connections. • Check the terminal / link history: • Is it a newly installed link? • Does the fault history for the link indicate a likely cause? • Has there been work done on the link in recent times, and if so, what? • Check that you have with you: • The appropriate spares. • The craft tool, the right the software revision to enable the craft tool to communicate with the equipment, and a connecting cable for craft tool access. • Any password and/or IP address required to secure craft tool access to the equipment. • Any special test equipment that may be needed. • Toolkit. • Key(s) for access to the site, and if necessary, the directions on how to get there. Where link alarms and performance monitors do not confirm the source of a fault condition, such as a dribbling BER reported at some point in the network, always check the alarms of the connected equipment. Never jump to a conclusion that a radio link is the problem. 280-200019-001 Rev 005a June 2007 9-5