9 Calculations
9.4 Return path calculation
Multimedia outlets
If the socket has separate user outputs for forward and return path (multimedia sockets),
you can define the socket in the library as follows:
1. In the library, define only one user output for the socket whose attenuation is described by
its own standard packet.
2. In the standard packet, enter the attenuation of the return path user output in the return
path frequency range, and in the forward path, the user output attenuation for
the forward path.
3. Do not forget to activate the Describe Attenuation via Standard Packet option
in the user output.
Example:
The 10/16dB multimedia outlet in the CDS_neutral.lib library.
AND Client Manual IV/C
© AND Solution GmbH
Page 331 of 452