Download High Performance Model QCPU(Q Mode)User`s Manual(Function
Transcript
14 SYSTEM CONFIGURATION OF MULTIPLE CPU SYSTEM MELSEC-Q 14.2.2 Precautions when using Q Series I/O modules and intelligent function modules (1) Compatible I/O modules All I/O modules (QX , QY ) are compatible with to multiple CPU system. They can be used by setting any of CPU No.1 to No.4 as a control CPU. (2) Compatible intelligent function modules (a) The intelligent function modules compatible with the multiple CPU system are those of function version B or later. They can be used by setting any of CPU No.1 to No.4 as a control CPU. (b) Q Series high speed count modules (QD62, QD62D, QD62E) are compatible with by multiple CPU system are those of function version A or later. They can be used by setting any of CPU No.1 to No.4 as a control CPU. (c) Q Series interruption modules (QI60) do not have a function version, but are supported by multiple CPU system. CPUs No.1 to No.4 can be set up as control CPUs. (d) Intelligent function modules of function version A can be used in multiple CPU system by setting CPU No.1 as a control CPU. However, only control CPU can be accessed from serial communication modules and other external modules. (MELSECNET/H, serial communication modules and other external modules cannot access noncontrol CPUs.) The "SP. UNIT VER. ERR (error code: 2150)" occurs if any of CPU No.2 to No.4 has been set as a control CPU, and the multiple CPU system will not be a started up. (3) Ranges of access to control and non-control modules In a multiple CPU system, non-control modules can be accessed by setting "I/O setting outside of the group" at the "Multiple CPU settings" dialog box in "PLC Parameter". The following table indicates accessibility to the control and noncontrol modules in the multiple CPU system. Accessibility Access target Control module Non-control module (I/O setting outside of the group) Disabled Enabled Input (X) Output (Y) Buffer memory Read Write Read Write : Accessible : Inaccessible REMARK • The function version of intelligent function modules can be confirmed at the rated name plate of the intelligent function module and with the GX Developer's "System monitor product information list window" (see Section 2.3.) • See Section 14.2.4 for details on restrictions on the number that can be used with intelligent function modules. 14 - 9 14 - 9
Related documents
Process CPU User`s Manual(Function Explanation
High Performance Model QCPU(Q Mode) User`s Manual(Hardware
High Performance Model QCPU(Q Mode)User`s Manual(Hardware
User`s Manual (Hardware Design, Maintenance and
Q-series basic Course(for GX Developer)
Clarke CWL12D Specifications
Mitsubishi Q62DAN Specifications
Mitsubishi Electronics LCD1760VM Computer Monitor User Manual
Basic Model QCPU(Q Mode)User`s Manual(Function Explanation
High Performance Model QCPU(Q Mode)User`s Manual(Function
Model Q2AS(H)CPU(S1)User`s Manual
CentaurStat 1 User Operating Instructions