Download High Performance Model QCPU(Q Mode)User`s Manual(Function
Transcript
7 FUNCTION MELSEC-Q 7.12 Sampling Trace Function POINT (1) Because the trace data and trace results are stored in the SRAM card (Q2MEM-1MBS) during sampling trace, the SRAM card is necessary. After installing the SRAM card to the High Performance model QCPU, execute sampling trace. (2) Because the trace data and trace results are not stored in the flash card and ATA card, sampling trace is not executed if the flash card (Q2MEM-2MBF, Q2MEM-4MBF) or ATA card (Q2MEM-8MBA, Q2MEM-16MBA, Q2MEM32MBA) is installed. (1) What is Sampling Trace Function? (a) This is a function to sample the device continuously on the High Performance model QCPU at specified timings. (b) The changes in the details of the device that program uses during debugging can be checked in the specified timing. The sampling trace function allows the read of device details if trigger conditions are satisfied. (c) The sampling trace samples the details of the specified device in a set interval (sampling cycle), and stores the trace results to the sampling trace file in the memory card. (d) The sampling trace file stores the trace condition data and trace execution data necessary to perform the sampling trace. When trace is started with the GX Developer, the trace is performed for the number of times set. The sampling trace area is 60 k bytes. The number of traces can be obtained by dividing 60 k bytes by the number of bytes specified as a device. The formula is: (Number of Bit Devices) / 8 + 2 (Number of Word Devices) High Performance model QCPU GX Developer Memory card Specified Sampling trace area device data Device area File register area 1 2 3 4 5 6 Data for 1st time Data for 2nd time Data for 3rd time Data for 4th time Data for 5th time Data for 6th time n-1 Data for (n-1)th time n Data for n th time Sampling trace area Read to the peripheral device 1 2 3 4 5 6 Displays the data for the specified amount Sampling trace data monitoring n-1 n When stored for n th time, the next data overwrites the 1st time data. If the trigger point is executed, the sampling trace area data is latched after sampling the number of times specified. Fig. 7.8 Sampling Trace Operation 7 - 45 7 - 45
Related documents
User`s Manual (Hardware Design, Maintenance and
User Guide - William Green
USER MANUAL
Process CPU User`s Manual(Function Explanation
Model Q2AS(H)CPU(S1)User`s Manual
High Performance Model QCPU(Q Mode)User`s Manual(Function
Manual - 首頁- B&K Precision
Mitsubishi Programmable Controller Training
QSCPU CPU Module User`s Manual (Hardware)
"user manual"
MELSEC-L CPU Module User`s Manual (Function Explanation
3 - Busy Bee Tools