Download User manual
Transcript
ENG 2.1.2 Technical specifications of the pRack PR100 Compact board Analogue inputs Analogue conversion Maximum number Type Time constant Input precision Classification of the measurement circuits 10-bit A/D converter embedded in CPU 8 Universal: 2 (inputs B1, B2) - CAREL NTC (-50T90°C; R/T 10 kΩ±1% at 25°C), NTC HT0T150 °C - Voltage 0 to 1 Vdc, 0…10 Vdc, 0 to 5 Vdc ratiometric - Current 0…20 mA or 4…20 mA. Input Resistance: 100 Ω Universal: 2 (inputs B3, B4) - CAREL NTC (-50T90°C; R/T 10 kΩ±1% at 25°C) NTC HT0T150 °C - Voltage 0 to 1 Vdc - PT1000 (-100T200 °C; R/T 1000 Ω at 0°C) Universal: 2 (inputs B5, B6) - CAREL NTC (-50T90°C; R/T 10 kΩ±1% at 25°C) NTC HT0T150 °C - Voltage 0 to 1 Vdc, 0…10 Vdc, 0 to 5 Vdc ratiometric - Voltage-free digital inputs, 5 mA Passive: 2 (inputs B7, B8) -CAREL NTC (-50T90°C; R/T 10kΩ±1% at 25°C) NTC HT0T150 °C - Voltage-free digital inputs, 5 mA Selectable via software 0,5 s ± 0.3 % of full scale Category 1 (IEC EN 61010-1) Tab. 2.b Important: the 21 Vdc available at terminal +VDC (J2) can be used to power any active probes. The maximum current is Imax=60 mA, thermally protected against short-circuits. To power the 0 to 5 Vdc ratiometric probes, use the 5V available at terminal +5Vref (J2). The maximum current is Imax=60 mA, thermally protected against short-circuits. Digital inputs Type Maximum number Minimum digital input impulse detection time Power supply Not optically-isolated, voltage-free contact 6: 2 + 4 multifunction analogue inputs Normally open (open-closed-open) Normally closed (closed-open-closed) internal 250 ms 250 ms Tab. 2.c Analogue outputs Type Maximum number Power supply Precision Resolution Settling time Maximum load Not optically-isolated 2: 1 PWM phase control output (Y1) with 5V pulse of programmable duration and 1 x 0 to 10 Vdc output (Y2) internal ± 2% of full scale on Y2 8 bit 2 s on Y2 1 k (10 mA) for 0…10 Vdc and 470 (10 mA) for PWM Tab. 2.d Note: the synchronicity for the PWM phase control output is taken from the SYNC input and G0 (J2). Digital outputs Important: The outputs can be divided into groups, depending on the insulation distance. The relays belonging to the same group have basic insulation between each other and therefore must have the same power supply (24 Vac or 110 to 230 Vac). Between groups there is double insulation and consequently these may have different voltages. Models PRK100X*A* & PRK100X*B* Makeup of the groups Type of relay Group 1 (J3) Type A Available with NC and NO contacts Features MOSFET photovoltaic relay Operating voltage 24 Vac/Vdc Maximum power 10 W Maximum number No. of changeover contacts Number of SSR outputs Group 2 (J10) Group 3 (J11) Type A Available with NO contacts Type B Available with NO contacts SPST, 1250 VA, 250 Vac, 5 A resistive. UL873: 1 A resistive, 1 A FLA, 6 A LRA, 250 Vac, D300 pilot duty (30.000 cycles). EN 60730-1: 1 A resistive, 1 A inductive, cosφ=0.6, 1(1) A (100.000 cycles) 7 None 2: outputs NO1 and NO2 (J3 and J10) Tab. 2.e 11 pRack +0300011EN rel. 1.2 - 04.12.2012