20: PULSE INSTRUCTIONS Timing Chart for Reversible Control with Single Pulse Output This program demonstrates a timing chart of the RAMP instruction when reversible control is enabled with single pulse output. RAMP I0 S1 D200 D1 M50 D204 = 1 (reversible control with single pulse output) Start Input I0 Control Direction D205 0 (Forward) 1 (Reverse) Steady Pulse Frequency Initial Pulse Frequency Output Pulse Q0 Control Direction Output Q1 Pulse Output ON M50 Pulse Output Complete M51 Pulse Output Status M52 • When input I0 is turned on, RAMP generates output pulses starting at the initial frequency designated by the value stored in data register D202. While the output pulses are sent out from output Q0, internal relay M50 remains on. • Operation modes 0 through 2: The pulse frequency increases according to the frequency change rate value stored in data register D203. • Operation mode 3: The pulse frequency increases as long as the frequency change time stored in data register D203. • While the output pulse frequency is on the increase, internal relay M52 remains on. • Depending on the control direction designated by the value stored in data register D205, control direction output Q1 turns off or on while D205 stores 0 (forward) or 1 (reverse), respectively. • When the output pulse frequency reaches the steady pulse frequency designated by the value stored in data register D201, internal relay M52 turns off. When the output pulse frequency starts to decrease, internal relay M52 turns on again. • When the quantity of generated output pulses reaches the preset value designated by data registers D206 and D207, RAMP stops generating output pulses. Then internal relay M50 and M52 turn off, and internal relay M51 turns on. • If the parameter values in D200 through D207 (except for D204) are changed while generating output pulses, the change takes effect when start input I0 is turned on for the next cycle. • If the value stored in D204 is changed after start input I0 has been turned on, the change can take effect only after the CPU starts again. • If start input I0 is turned off before reaching the preset value, RAMP stops generating output pulses immediately, then internal relay M50 turns off and internal relay M51 turns on. When input I0 is turned on again, RAMP restarts to generate output pulses for another cycle, starting at the initial pulse frequency. « MICROSMART USER’S MANUAL » 20-19
Related documents
G2A user guideV11.2.2
IDEC MicroSmart Pentra PLC User`s Manual
Programmable Logic Controllers
"user manual"
MicroSmart Pentra PLC Logic Controllers
Specifications - Idec Elektrotechnik GmbH
Complete PLC Catalog
(FC4A) Series PLCs
opennet controller - Steven Engineering
IDEC MicroSmart User Manual
"user manual"
IDEC ONC Series OpenNet Controller User`s Manual