Transcript
Encoder > General Alerts: Alert Action Table 6.1.1 General EAS To construct and send an EAS alert, you need to set six items on the General EAS page: The EAS alert code; The starting time (effective time) of the alert; The alert duration The FIPS locations codes for the alert; The audio message, if any, for the alert. The audio announcement message, if any that will precede and follow the alert. The values for these items are presented using pull-down and selection menus. Select EAS Code To set the EAS code, select from the codes presented under the Select Available EAS Code pull-down menu. The codes shown are the ones that were added to the list on the Setup >Encoder screen. If the list needs to be corrected, use the link Select Available EAS Code to return to the Setup > Encoder screen. Configure Available EAS Types for Encoder as needed. See section 5.9. Then return to the Encoder >Send EAS >General page to continue constructing the alert. NOTE: Only specially configured One-Net’s will allow origination of the National alerts Emergency Action Notification & Termination (EAN & EAT). - 85 -