Download - Worcester Bosch
Transcript
Installation 8.2 General connection of mains water and gas components 8.2.1 General The water and gas connections to the boiler can be made in either of 2ways: • using a pump group ( fig. 12) • without a pump group. 8.2.3 Install the water and gas connections to the boiler without a pump group ▶ Connect all pipes making sure that they are not bent or twisted to cause any stress. CAUTION: ▶ Do not use galvanised radiators or pipes. ▶ Make sure that the connections are tight and carry out a gas and water leakage test after completing the connection work. DANGER: Danger of fatal accident from explosive fumes. ▶ Only carry out work on gas pipes and fittings if you are Gas Safe / ACS registered. Installing the gas connection DANGER: Danger of fatal accident from explosive fumes. ▶ Make sure that the factory-fitted flat rubber seal is located in the threaded connection (boiler side) ( fig. 13, detailed picture). 6 720 648 726-012.1TD Fig. 12 Pump group (accessory) The circulation pump is not factory-installed in the boiler. This pump is included in the pump group (accessory). If you do not make use of a pump group, you have to install a separate circulation pump under the boiler. This pump must be selected so that the volume flow through the boiler is sufficient to handle the maximum boiler capacity. Correct pump selection see chapter 8.2.8 “Selecting and installing the pump”, page 16. The pump group has been developed specifically for this boiler and has already been fitted with the correct pump. The pump group also includes various fittings, such as service fittings, a pressure relief valve, a pressure gauge, a gas valve etc. This makes installing the appliance easier to overcome resistance in the heating circuit. 6 720 648 726-013.1TD Both installation methods are described below. Fig. 13 Rubber seal ▶ Decide whether you would like to connect the heating device with or without a pump group. If you don’t use our pump group, you have to calculate a separate pump. Make sure, that the pump is large enough, for the flow to overcome resistance in the heating circuit. The gas installation must be installed in accordance with BS 6891. 8.2.2 Install the water and gas connections to the boiler using a pump group (accessory) The central heating system should be installed in accordance with BS 6798 and, in addition, for small bore and micro bore systems, BS 5449 or EN 12823. The gas installation must be installed in accordance with BS 6891. ▶ Install the pump group on the boiler in accordance with the enclosed installation instructions. CAUTION: Pipework from the meter to the boiler must be of adequate size. The complete installation must be tested for gas leakage and purged as described in IGE/UP/1b. NOTICE: For the installation of the gas valve a gas valve connector 1" [1] is necessary. To order, see address on the back of this document. CAUTION: ▶ Do not use galvanised radiators or pipes. 6720813171 (2015/04) 15