P.no.
Error name
P 0030
(4) OvertempMotor_MON_Device_DIN3
(7)
(10)
(13)
Interior temperature evaluation
I2xt integrator has exceeded motor protection limit value
(permissible current/time area)
I2xt power stage protection limit value exceeded
External
(1) External_MPRO_INPUT
(12)
Heat sink temperature too high
PowerAmplifier
(1) I2tPowerAmplifier_MON_Device
(11)
PTC to DIN3
I2tMotor
(1) I2tMotor_MON_I2t
External error message
CAN
(1) ComOptCan_BusOff
CAN option: BusOff error
(2) ComOptCan_Guarding
CAN option: Guarding error
(3) ComOptCan_MsgTransmit
CAN option: Unable to send message
(4) ComOptCan_HeartBeat
CAN option: Heartbeat error
(5) ComOptCan_Addr
CAN option: Invalid address
(6) ComOptCan_PdoMappingError
CAN option: Mapping error
(7) ComOptCan_SyncTimeoutError
CAN option: Synchronization error
SERCOS
Error name
P 0030
OvertempDevice
(1) OvertempDevice_MON_Device
(9)
P.no.
OvertempInverter
(1) OvertempInverter_MON_Device
(8)
Description of error
(14)
(15)
Description of error
(3) ComOptSercos_CableBreak
SERCOS: Cable break
(4) ComOptSercos_DataDisturbed
SERCOS: Disturbed data transmission
(5) ComOptSercos_MasterSync
SERCOS: Faulty synchronization
(6) ComOptSercos_MasterData
SERCOS: Data telegrams missing
(7) C
omOptSercos_AddressDouble
SERCOS: Duplicate address
(8) C
omOptSercos_Phase
SwitchUp
SERCOS: Faulty phase switching (Up shift)
(9) C
omOptSercos_Phase
SwitchDown
SERCOS: Faulty phase switching (Down shift)
(10) C
omOptSercos_Phase
SwitchAck
SERCOS: F aulty phase switching (missing
acknowledgement)
(11) ComOptSercos_InitParaList
SERCOS: Faulty initialization of SERCOS parameter lists
(12) ComOptSercos_
RunTimeError
SERCOS: Various runtime errors
(13) ComOptSercos_Watchdog
SERCOS: Hardware watchdog
(14) ComOptSercos_Para
SERCOS: E rror in parameterization (selection of OP mode,
IP times, etc...)
EtherCat
(1) C
omOptEtherCat_Sm
Watchdog0
EtherCat: Sync-Manager0 - Watchdog
(2) C
omOptEtherCat_Wrong
EepData
EtherCat: Parameter error, parameter data implausible
(3) ComOptEtherCat_RamError
EtherCat: Internal RAM error
Parameters
SERCOS: Hardware initialization
(1) P arameter_MON_Device_
Current
Error in current monitoring initialization
(1) ComOptSercos_HardwareInit
(2) ComOptSercos_IllegalPhase
SERCOS: Invalid communication phase
(2) Parameter_MON_I2t
Motor protection