Download iVPI, CAA Software Reference Guide
Transcript
NVSP Compiler Files 11.1.2.8 EQUIPMENT LOCATION Records This record identifies the physical location of the equipment for which this NVSP Program is being provided. The record format is: EQUIPMENT LOCATION = location • location is the physical location of the iVPI module(s) in which this program is located, a maximum of 40 characters in length. For example: EQUIPMENT LOCATION = OLD RELAY ROOM, RACK A3 11.1.2.9 DESIGNER Record This record identifies the name(s) of the individual(s) responsible for the design of this NVSP Program. The record format is: DESIGNER = name • name is the name(s) of the designer(s), a maximum of 40 characters in length. For example: DESIGNER = JOHN Q. DESIGNER 11.1.2.10 CHECKER Records This record identifies the name(s) of the person(s) responsible for checking all aspects of the NVSP compiler input file, including the application logic, the I/O, and the parameter definitions. The record format is: CHECKER = name • name is the name(s) of the individual(s) responsible for checking these equations, a maximum of 40 characters in length. For example: CHECKER = JUNE D. CHECKER P2512F, Rev. G, Aug/15 11-7 Alstom Signaling Inc.