Download TRACKER Remote Diagnostic Analyzer
Transcript
Functions Table 5–2. System Configuration, Editable Parameters (Cont) Parameter Description Log / Capture Files Flush Interval The frequency with which to purge old files. This value is in hours and is an offset from the flush time. Example: a flush interval of 4 hours and a flush time of 0400 results in the files being flushed at 8:00, 12:00, 16:00, 20:00 and 24:00 (midnight). Include Device Name Add a Device Name field to the event data in log reports, whether or not the report includes data from multiple devices. Default (unchecked) is to add a Device Name field only if the report is for multiple devices. No Initial Snapshot Do not include the initial snapshot of all variable values in log reports. Default (unchecked) is to include an initial snapshot. Select the Devices button to bring up the Select Device Window to edit the configuration information of any defined device. NOTE Only devices available before the Edit System Configuration Window is opened are available when the Devices button is selected. If the number of devices entry is modified, that change does not take affect until after the system configuration information is saved. Expected result: If the Save button is selected, changes to the system configuration information are saved. If the Cancel button is selected, any changes made are discarded. If the Save option is selected after the changes are saved, TRACKER restarts with the new settings. P2307, Rev. Oct/07 5–11 Alstom Signaling Inc.