Download Print ( 2.9 MB)
Transcript
B.3 XSCF Event Logs List 07:PDOWN [: Power outage/power recovery] (*el) 08:Nodeself [: Node self-error] (*el) 09:Mount [: Mount error (RCI device only)] 0a:Change [: Status transition event (RCI device only)] Detailed code: xVVqqrr00 Explanation: A power outage occurred or power was restored. VV indicates the detailed event, qq indicates the first item of detailed information, and rr indicates the second item of detailed information. The definition of VV is as follows: ― x01 : A power outage occurred. ― x02 : Power was restored. When VV is "x01, The power outage", qq is "0". When VV is "x02, The power recovery", qq is ignored. The definitions of rr are as follows: The rr the second item of detailed information : 0 7 ― bit 0 : 1_ Need monitoring for a power recovery. 0_ Not need monitoring for a power recovery. ― bit 1 : 1_ ACOFF, 0_ACFAIL ― bit 2 : 1_ UPC, 0_ Not UPC ― bit 3 : Reserved ― bits 4-7 : PSU number 0-2. When a power outage/power recovery is for UPC, bits are "0". Detailed code: x00VVppss Explanation: A node-specific error occurred. VV indicates the detailed event, pp indicates the first item of detailed information, and ss indicates the second item of detailed information. The definition of VV is as follows: ― x90 : A status check timeout occurred. ― x91 : The IO node address was duplicated. ― x93 : An unregistered node is found. ― x95 : The sensor failed. When VV is "x95, The sensor failed", ss is sensor number. The definitions of pp are as follows: ― x01 : The system control bus switcher ― x02 : SB thermal sensor ― x03 : FAN sensor, ss is x00. ― x04 : Inlet sensor ― x05 : CPU thermal sensor Detailed code: x01mmqq00 Explanation: The number of parts was more than the expected value for the installation conditions. mm indicates the part name number and qq indicates the device-dependent information. The definition of mm is as follows: ― x01 : Power supply unit ― x02 : Fan ― x03 : Temperature sensor ― x04 : Battery for memory backup ― x05 : UPS ― x06 : Humidity sensor Detailed code: x02mmqq00 Explanation: The number of parts was less than the expected value for the installation conditions. mm indicates the part name number and qq indicates the device-dependent information. The definition of mm is the same as described above. Detailed code: x03mmqq00 Explanation: The mounting location of the part is different from the correct position. mm indicates the part name number and qq indicates the device-dependent information. The definition of mm is the same as described above. Detailed code: xVV000000 Explanation: A status transition event for the device occurred. The definition of VV is as follows: ― x01 : The status of the power supply unit changed. ― x02 : The status of the fan changed. ― x03 : The status of the temperature sensor changed. ― x04 : The status of the battery for memory backup changed. ― x05 : The status of the UPS changed. ― x06 : The status of the humidity sensor changed. ― x07 : The status of the HDD changed. B-73 All Rights Reserved,Copyright (C) FUJITSU LIMITED