Download Print ( 3.1 MB)
Transcript
the addition of descriptions about the error code. The sixth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition. z Chapter 1, "Overview of XSCF": z ― In "Types of Connection to XSCF", a description of tty-a console path is added. Chapter 6, "How to Use the XSCF Command Shell": z ― In "nodeled" command, note is added. Chapter 7, "XSCF SNMP Agent function": In "About Traps", Note about the target parts for trap is added. Appendix A, "Warning And Information Messages": z ― "Control execution messages during the monitoring for foreseeable faults " is added. Appendix B, "XSCF Log Information": z ― "XSCF Error Log List" are corrected. ‐ Error codes 07060030, 07140031, 0801000X, 0A00000X, 0A1z000X, 0C00000X, 10100030, 150z000n, 153A000X, 1A00000n, 21000045, 250000FF-(2), 33000039, 330000FF, 330000FF_(2), 4D0008FF, 4E07200n, 5080000n, 9080000n, D080000n and xx0000FF are added. ‐ Error code number is corrected as below: xx0B0030 -> xxxB0030, xx0C000n -> xxxC000n, xx0D006n -> xxxD006n ‐ In Table "POST/OBP test phase number", USB is added. ― "XSCF Power Log List" are corrected, added or deleted. ‐ Power-on: In the "Retry" definition, the "The retry is caused by for the server cooling." is added. z ― "XSCF Event Log List" are corrected. ‐ Temperature change event: A definition of x30, "The PSU cooling is done by control of the monitoring for foreseeable fault." is added. Appendix C, "XSCF MIB ": In Table C-9, C-13 and C-14, descriptions are added. Summary of Changes in Fifth Edition The current, fifth edition of this manual differs from previous edition principally by containing the addition of descriptions about Troubleshooting. The fifth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition. z Chapter 3, "Connecting XSCF or Server": ― In “Connecting Terminals to XSCF”, Not to use the XSCF command to set whether to use a standard console via the serial port (tty-a) or the SCF-LAN port but to do by the Machine Administration Menu, the description is corrected. z ― In “Connecting Terminals to XSCF”, a description of setting of the terminal software on the serial port(tty-a) terminal is added. Chapter 5, "How to Use the XSCF Web Function ": z ― In "Overview of the XSCF Web Function", sample pages of Web browser are added. Chapter 6, "How to Use the XSCF Command Shell": z ― In set-console-device, "lan" option is deleted. ― The command of “send-break” is added. Appendix A, "Warning And Information Messages": ― "System messages" are corrected. ‐ “Hardware configuration error” is added. ‐ RCI address is added in “Detected failure on the RCI node”. ‐ Messages of the errors detected by only POST/OBP are added. vii All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003, 2004,2005