Download operations from touch keypad

Transcript
n Arm Partition (Disarm) (1.7)
This option will allow you to Arm or Disarm the Partitions one by one.
n Zone Test (1.8)
This option will allow you to test the Zones.
+
1. Press A or B to view the Zone test option:
The single partition can be directly armed from Partition status (refer to “View Partition status (MAIN
PAGE) on LCD Keypads”).
1. Press A or B to view the Arm Part. option:
USER
Arm Part.
1.7
1.8
2. Press ENTER to select the option:
Zone test
1=Beep_ 2=Siren_
2. Press ENTER to select the option:
Arm.Part.
USER
Zone test
---
3. Enter the Identification number of the required Partition:
Arm.Part. 001
label Part. 01
3. Select the signal to activate in correspondence of
the test of the Zones:
Ø 1, in correspondence of the test of the Zone the keypad will emit a Beep;
Ø 2, in correspondence of the test of the Zone the siren
will emit an alarm signal.
options 1 and 2 can be selected at the same
+ The
time.
4. Press ENTER to confirm.
4. Press:
Ø ON for Away Arming;
ZONE TEST
Part= -- Zone --
label Part. 01
Armed
5. Press C or D to select ALL the Zones relevant to a
Partition (Part=) or the Zones individually (Zone=).
Press A or B to select the required Partition/Zone.
Ø OFF for Disarming;
label Part. 01
DISARMED
Label. zona 002
Part -- Zona=002
Ø A for Stay Arming;
6. Press ENTER to include in the test the selected
Partition/Zone, then go back to step 5 to select another Zone/Partition or to next step to start the test.
label Part. 01
Stay Armed
Ø B for Zero Delay – Stay Arming.
Test on going
label Part. 01
No delay Armed
The keypad quits from the User Menu.
ABSOLUTA
7. Press ON to active the test.
In this phase, you can test the alarm and tamper on the
selected Zones. You can see the test result on the keypad.
OPERATIONS FROM LCD KEYPAD
41