Download PDO 5580 - Applied Motion
Transcript
Connecting the Motor Six lead motors can be connected in series or center tap. In series mode, motors produce more torque at low speeds, but cannot run as fast as in the center tap configuration. In series operation, the motor should be operated at 30% less than the rated current to prevent overheating. Wiring diagrams for both connection methods are shown below. AMPS/ PHASE 1.3 AMPS/ PHASE 2.3 AMPS/ PHASE 2.5 AMPS/ PHASE 2.7 AMPS/ PHASE 3.7 AMPS/ PHASE 3.9 AMPS/ PHASE 4.1 AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 Note: NC means not connected to anything. A+ 1.5 A– Grn/Wht White Green A+ NC Red B– Red/ Wht Black NC White 1.7 Green B– 6 Leads Series Connected AMPS/ PHASE 6 lead motor Red B+ Red/ Wht Black B+ AMPS/ PHASE 2.9 AMPS/ PHASE 3.1 AMPS/ PHASE 4.3 AMPS/ PHASE 4.5 AMPS/ PHASE NC 6 Leads Center Tap Connected -6- 0.2 0.4 0.8 1.6 2.0 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 AMPS/ PHASE 1.1 NC 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 White B– 4 Leads 6 lead motor AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 Yellow B+ Grn/Wht 4.9 Blue 0.9 A– AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4.7 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 3.5 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 3.3 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 2.1 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 1.9 4 5 6 7 8 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 A– AMPS/ PHASE 4 5 6 7 8 4 lead motor 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 Four lead motors can only be connected one way. Please follow the sketch at the right. 0.7 4 5 6 7 8 A+ Red AMPS/ PHASE 0.2 0.4 0.8 1.6 2.0 4 5 6 7 8 You must now decide how to connect your motor to the drive. 0.5 4 5 6 7 8 Never connect the motor to the driver when the AC power is on. Secure any unused motor leads. Never disconnect the motor while the AC power is on. Never connect motor leads to ground or to a power supply. 4 5 6 7 8 ! Current Setting Table -19- 5.1 AMPS/ PHASE 5.3 AMPS/ PHASE 5.5 AMPS/ PHASE