Connecting the Motor
Six lead motors can be connected in series or center tap. In series mode, motors
produce more torque at low speeds, but cannot run as fast as in the center tap
configuration. In series operation, the motor should be operated at 30% less than
the rated current to prevent overheating. Wiring diagrams for both connection
methods are shown below.
AMPS/
PHASE
1.3
AMPS/
PHASE
2.3
AMPS/
PHASE
2.5
AMPS/
PHASE
2.7
AMPS/
PHASE
3.7
AMPS/
PHASE
3.9
AMPS/
PHASE
4.1
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
Note: NC means not connected to anything.
A+
1.5
A– Grn/Wht
White
Green
A+
NC
Red
B–
Red/
Wht
Black
NC
White
1.7
Green
B–
6 Leads Series Connected
AMPS/
PHASE
6
lead
motor
Red
B+
Red/
Wht
Black
B+
AMPS/
PHASE
2.9
AMPS/
PHASE
3.1
AMPS/
PHASE
4.3
AMPS/
PHASE
4.5
AMPS/
PHASE
NC
6 Leads Center Tap Connected
-6-
0.2
0.4
0.8
1.6
2.0
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
AMPS/
PHASE
1.1
NC
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
White
B–
4 Leads
6
lead
motor
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
Yellow
B+
Grn/Wht
4.9
Blue
0.9
A–
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4.7
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
3.5
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
3.3
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
2.1
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
1.9
4 5 6 7 8
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
A–
AMPS/
PHASE
4 5 6 7 8
4
lead
motor
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
Four lead motors can only be connected
one way. Please follow the sketch at the right.
0.7
4 5 6 7 8
A+
Red
AMPS/
PHASE
0.2
0.4
0.8
1.6
2.0
4 5 6 7 8
You must now decide how to connect your
motor to the drive.
0.5
4 5 6 7 8
Never connect the motor to the driver when the AC power is on.
Secure any unused motor leads.
Never disconnect the motor while the AC power is on.
Never connect motor leads to ground or to a power supply.
4 5 6 7 8
!
Current Setting Table
-19-
5.1
AMPS/
PHASE
5.3
AMPS/
PHASE
5.5
AMPS/
PHASE