8-6 Triggering Model 2700 Multimeter/Switch System User’s Manual Output trigger After the device action, an output trigger occurs and is available at the rear panel Trigger Link connector. This trigger can be used to trigger another instrument to perform an operation (e.g., select the next channel for an external scan). Reading hold (autosettle) With hold enabled (HOLD annunciator on), the first processed reading becomes the “seed” reading and operation loops back within the device action block. After the next reading is processed, it is checked to see if it is within the selected hold window (0.01%, 0.1%, 1%, or 10%) of the “seed” reading. If the reading is within the window, operation again loops back within the device action block. This looping continues until the specified number (2 to 100) of consecutive readings are within the window. If one of the readings is not within the window, the instrument acquires a new “seed” reading and the hold process continues. When a hold reading is acquired, an audible beep is sounded (if enabled) and the reading is considered a “true measurement.” The reading is held on the display until an “out of window” reading occurs to restart the hold process. For remote operation, the hold process seeks a new “seed” once it has been satisfied and the reading has been released. For basic front panel operation, the hold process does not seek a new “seed” until the held condition is removed. NOTE Hold cannot be used when scanning. Hold example 1. 2. 3. 4. 5. 6. 7. 8. Press SHIFT and then HOLD to display the present window (0.01%, 0.1%, 1%, or 10%). To change the window, press the Δ or ∇ key to display the desired window. Press ENTER. The present hold count is displayed (2 to 100). To change the hold count, use the , , Δ, and ∇ keys to display the desired count. Press DCV to measure DC voltage. Apply the test signal to the input of the Model 2700. Once the signal becomes stable enough to satisfy the hold condition, the reading is released and the beeper sounds (if enabled). Remove the hold condition by disconnecting the signal from the input. Hold will then seek a new “seed.” To disable HOLD, press SHIFT and then HOLD. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com
Related documents
Model 2700 Multimeter/Switch System
User`s Manual
Model 2701 Ethernet-Based DMM / Data Acquisition
User Manual
Model 27XXIntegra Series Quick Start Guide
Series 3700A System Switch/Multimeter User`s Manual
Training Manual - System Administration V4-7
Manual - Test Equipment Depot
Integra Series
PA-818B (Model 7711/7712 User`s Guide)