Download Liebert PEX Technical Data Manual

Transcript
Technical Data
Liebert PEX Large Frame
Upflow - DX Scroll compressors + FC fans
Air/Water Cooled
Model Size
PEX
1020
1025
1030
2035
2045
2055
2040
Rated Capacity 24°C DB, 50% RH, 45° Condensing, CW Based on 7˚C EWT, 12˚C LWT
DX
Total kW
19.4
22.1
29.2
36.5
44.4
52.0
39.5
Sensible kW
18.3
20.7
25.9
34.8
40.7
46.1
37.2
CW
Total kW
23.2
25.3
28.5
47.5
53.4
57.3
50.0
Sensible kW
19.5
21.7
25.4
38.0
43.4
47.2
40.1
Rated Capacity 24°C DB, 45% RH, 45° Condensing, CW Based on 7˚C EWT, 12˚C LWT
Dual Cool
2050
2060
3070
3080
3090
45.7
42.0
54.9
45.1
57.9
51.6
62.7
53.0
71.8
66.2
83.6
69.5
79.4
69.2
83.6
69.5
87.2
77.5
91.9
78.5
56.4
55.1
55.7
54.1
15,390
70.0
69.5
73.5
70.8
19,190
76.7
73.5
73.5
70.8
19,190
83.5
82.2
81.4
80.2
22,770
DX
Total kW
19.3
21.9
28.1
36.5
42.9
49.7
39.5
44.5
Sensible kW
19.1
21.7
27.4
36.2
42.6
48.8
39.2
44.2
CW
Total kW
20.5
22.2
25.8
42.2
47.0
50.4
44.2
48.7
Sensible kW
19.9
22.2
25.8
38.6
44.1
48.0
40.8
45.9
Air Flow
m3/h
5,400
6,300
7,870
9,720
11,610
13,030
10,440
12,240
Evaporator Fan - Forward curve FC centrifugal fan, induction motor, auto-tensioning belt drive
No. of fan assemblies
1
1
1
2
2
2
Std. Motor - kW
2.2
2.2
3.0
2.2
2.2
2.2
Evaporator Coil - Copper tubes with rifled bore tubes, louvred aluminium fins
No. of rows
6
6
6
6
Fin series - FPM(FPI)
Compressor - Copeland Compliant Scroll with Crankase Heater
6
No. of compressors
Unit cooling steps
Safety controls - kPa
Humidification Control
1
1
1
1
1
50Hz
2
2.2
2
2.2
2
3.0
3
2.2
3
2.2
3
3.0
6
6
6
6
6
6
2
2
2
6
550 (14)
1
2
2
2
2 via HGBP
LP cut out/in(auto reset) 140/420, HP cut out (manual reset) 2800
Infrared - kg/h
4.5
4.5
4.5
10
10
10
Opt. Electrode - kg/h
5
5
5
10
10
10
Dehumidification control- Standard HVAC dehumidification methology utilised
Reheat - Single stage, electric heater elements
10
10
10
10
10
10
10
10
10
10
10
10
1 stage - kW
6
6
6
9
9
Opt. 2 stage - kW
12
12
12
18
18
Filter - Metal Frame, Deep V dry media disposable G4 type filter
9
18
9
18
9
18
9
18
12
24
12
24
12
24
Nominal W x D x H - mm
Qty
1
1
1
2
2
2
Full Load Current - 400 Volts, 3 phase+N+E, 50 Hz Supply - Std DX unit only
2
2
2
3
3
3
60.2
65.3
71.1
82.3
RFLA 24.0
26.1
33.1
42.6
48.4
53.4
42.0
46.2
Water Cooled Condenser - 316SS Brazed Plate Heat Exchanger- 3 Way MBV (Opt. 2 Way MBV)
No. of Condensers
No. of MBV
Valve Size
Flow - l/s
PD - kPa
Unit Connections
1
1
DN25
1.0
48
1
1
DN25
1.2
62
1
1
DN25
1.5
72
1
1
DN25
1.9
67
1
1
DN25
2.3
81
1
1
DN32
2.7
71
2
2
DN25
2.1
50
2
2
DN25
2.4
63
2
2
DN25
3.0
72
2
2
DN25
3.7
63
2
2
DN25
4.2
79
2
2
DN25
4.5
75
Hot Gas - O.D.
Qty
Liquid - O.D.
Qty
Condenser Water Supply - I.D.
Qty
Condenser Water Return - O.D.
Qty
CW Supply - I.D.
CW Return - O.D.
Drain - Barb - mm
Hum. Supply - BSP - M
Unit Dimensions & Weight
22
1
16
1
35
1
35
1
25
25
19
1/2"
22
1
16
1
35
1
35
1
25
25
19
1/2"
22
1
16
1
35
1
35
1
25
25
19
1/2"
22
1
16
1
35
1
35
1
35
35
19
1/2"
22
1
16
1
35
1
35
1
35
35
19
1/2"
22
1
16
1
35
1
35
1
35
35
19
1/2"
22
2
16
2
35
2
35
2
35
35
19
1/2"
22
2
16
2
35
2
35
2
35
35
19
1/2"
22
2
16
2
35
2
35
2
35
35
19
1/2"
22
2
16
2
42
2
42
2
42
42
19
1/2"
22
2
16
2
42
2
42
2
42
42
19
1/2"
22
2
16
2
42
2
42
2
42
42
19
1/2"
Width - mm
Depth - mm
Height - mm
Unit Weight - kg
Unit Footprint
853
873
853
873
853
873
1703
873
1703
873
1703
873
1703
873
1703
873
1703
873
2553
873
2553
873
2553
873
350
360
370
600
610
630
650
670
700
970
990
1030
Unit only - m2
0.74
1.47
0.74
1.47
0.74
1.47
1.49
2.93
1.49
2.93
1.49
2.93
1.49
2.93
1.49
2.93
1.49
2.93
2.23
4.40
2.23
4.40
2.23
4.40
Incl. Service area - m2
Service Access min - mm
1970
850
Notes
1.
2.
3.
4.
All rated capacities are nominal values based on an ESP for Downflow 20pa and for Upflow 50Pa, at sea level for R407C & R22. For net capacities, deduct fan input power. Refer to the Liebert PEX Rating Program for specific input conditions, air flow, and configuration.
Minimum unit depth without front panels and hinges is 841mm. Weights shown are for water cooled DX models only.
Input power supply 400V +/-15%, 50Hz +/- 2. RFLA is for the standard configuration unit only and excludes all heat rejection equipment, Chillers and Pumps etc. RFLA based on standard unit. Refer to Liebert PEX Rating Program & User Manual for electrical data on optional equipment.
All information and Technical Data are subject to change without notice.
Technical Data Manual
2-7