Download Liebert PEX Technical Data Manual
Transcript
Technical Data Liebert PEX Large Frame Upflow - DX Scroll compressors + FC fans Air/Water Cooled Model Size PEX 1020 1025 1030 2035 2045 2055 2040 Rated Capacity 24°C DB, 50% RH, 45° Condensing, CW Based on 7˚C EWT, 12˚C LWT DX Total kW 19.4 22.1 29.2 36.5 44.4 52.0 39.5 Sensible kW 18.3 20.7 25.9 34.8 40.7 46.1 37.2 CW Total kW 23.2 25.3 28.5 47.5 53.4 57.3 50.0 Sensible kW 19.5 21.7 25.4 38.0 43.4 47.2 40.1 Rated Capacity 24°C DB, 45% RH, 45° Condensing, CW Based on 7˚C EWT, 12˚C LWT Dual Cool 2050 2060 3070 3080 3090 45.7 42.0 54.9 45.1 57.9 51.6 62.7 53.0 71.8 66.2 83.6 69.5 79.4 69.2 83.6 69.5 87.2 77.5 91.9 78.5 56.4 55.1 55.7 54.1 15,390 70.0 69.5 73.5 70.8 19,190 76.7 73.5 73.5 70.8 19,190 83.5 82.2 81.4 80.2 22,770 DX Total kW 19.3 21.9 28.1 36.5 42.9 49.7 39.5 44.5 Sensible kW 19.1 21.7 27.4 36.2 42.6 48.8 39.2 44.2 CW Total kW 20.5 22.2 25.8 42.2 47.0 50.4 44.2 48.7 Sensible kW 19.9 22.2 25.8 38.6 44.1 48.0 40.8 45.9 Air Flow m3/h 5,400 6,300 7,870 9,720 11,610 13,030 10,440 12,240 Evaporator Fan - Forward curve FC centrifugal fan, induction motor, auto-tensioning belt drive No. of fan assemblies 1 1 1 2 2 2 Std. Motor - kW 2.2 2.2 3.0 2.2 2.2 2.2 Evaporator Coil - Copper tubes with rifled bore tubes, louvred aluminium fins No. of rows 6 6 6 6 Fin series - FPM(FPI) Compressor - Copeland Compliant Scroll with Crankase Heater 6 No. of compressors Unit cooling steps Safety controls - kPa Humidification Control 1 1 1 1 1 50Hz 2 2.2 2 2.2 2 3.0 3 2.2 3 2.2 3 3.0 6 6 6 6 6 6 2 2 2 6 550 (14) 1 2 2 2 2 via HGBP LP cut out/in(auto reset) 140/420, HP cut out (manual reset) 2800 Infrared - kg/h 4.5 4.5 4.5 10 10 10 Opt. Electrode - kg/h 5 5 5 10 10 10 Dehumidification control- Standard HVAC dehumidification methology utilised Reheat - Single stage, electric heater elements 10 10 10 10 10 10 10 10 10 10 10 10 1 stage - kW 6 6 6 9 9 Opt. 2 stage - kW 12 12 12 18 18 Filter - Metal Frame, Deep V dry media disposable G4 type filter 9 18 9 18 9 18 9 18 12 24 12 24 12 24 Nominal W x D x H - mm Qty 1 1 1 2 2 2 Full Load Current - 400 Volts, 3 phase+N+E, 50 Hz Supply - Std DX unit only 2 2 2 3 3 3 60.2 65.3 71.1 82.3 RFLA 24.0 26.1 33.1 42.6 48.4 53.4 42.0 46.2 Water Cooled Condenser - 316SS Brazed Plate Heat Exchanger- 3 Way MBV (Opt. 2 Way MBV) No. of Condensers No. of MBV Valve Size Flow - l/s PD - kPa Unit Connections 1 1 DN25 1.0 48 1 1 DN25 1.2 62 1 1 DN25 1.5 72 1 1 DN25 1.9 67 1 1 DN25 2.3 81 1 1 DN32 2.7 71 2 2 DN25 2.1 50 2 2 DN25 2.4 63 2 2 DN25 3.0 72 2 2 DN25 3.7 63 2 2 DN25 4.2 79 2 2 DN25 4.5 75 Hot Gas - O.D. Qty Liquid - O.D. Qty Condenser Water Supply - I.D. Qty Condenser Water Return - O.D. Qty CW Supply - I.D. CW Return - O.D. Drain - Barb - mm Hum. Supply - BSP - M Unit Dimensions & Weight 22 1 16 1 35 1 35 1 25 25 19 1/2" 22 1 16 1 35 1 35 1 25 25 19 1/2" 22 1 16 1 35 1 35 1 25 25 19 1/2" 22 1 16 1 35 1 35 1 35 35 19 1/2" 22 1 16 1 35 1 35 1 35 35 19 1/2" 22 1 16 1 35 1 35 1 35 35 19 1/2" 22 2 16 2 35 2 35 2 35 35 19 1/2" 22 2 16 2 35 2 35 2 35 35 19 1/2" 22 2 16 2 35 2 35 2 35 35 19 1/2" 22 2 16 2 42 2 42 2 42 42 19 1/2" 22 2 16 2 42 2 42 2 42 42 19 1/2" 22 2 16 2 42 2 42 2 42 42 19 1/2" Width - mm Depth - mm Height - mm Unit Weight - kg Unit Footprint 853 873 853 873 853 873 1703 873 1703 873 1703 873 1703 873 1703 873 1703 873 2553 873 2553 873 2553 873 350 360 370 600 610 630 650 670 700 970 990 1030 Unit only - m2 0.74 1.47 0.74 1.47 0.74 1.47 1.49 2.93 1.49 2.93 1.49 2.93 1.49 2.93 1.49 2.93 1.49 2.93 2.23 4.40 2.23 4.40 2.23 4.40 Incl. Service area - m2 Service Access min - mm 1970 850 Notes 1. 2. 3. 4. All rated capacities are nominal values based on an ESP for Downflow 20pa and for Upflow 50Pa, at sea level for R407C & R22. For net capacities, deduct fan input power. Refer to the Liebert PEX Rating Program for specific input conditions, air flow, and configuration. Minimum unit depth without front panels and hinges is 841mm. Weights shown are for water cooled DX models only. Input power supply 400V +/-15%, 50Hz +/- 2. RFLA is for the standard configuration unit only and excludes all heat rejection equipment, Chillers and Pumps etc. RFLA based on standard unit. Refer to Liebert PEX Rating Program & User Manual for electrical data on optional equipment. All information and Technical Data are subject to change without notice. Technical Data Manual 2-7