Mask Index Descr. display Descr. Capacity control Type of Compressor Capacity-control Evaporator type Cool Type of Evaporator / Condenser Def UOM Min Max 0 --- 0 3 0 --- 0 4 0 --- 0 4 Hdb02 Heat Min saturation temp. Cooling mode Hdb03 Heating mode Defrost mode Max saturation temp. Cooling mode Hdb04 Heating mode Defrost mode High SuperHeat alarm threshold Hdb05 Auto SuperHeat Man param. CH-Circuit/EEV Ratio Auto Hdc01 CH-Proportional gain Auto CH-Integral time Auto HP-Circuit/EEV Ratio Auto HP-Proportional gain Auto Hdc02 HP-Integral time Auto Type of Evaporator / Condenser Temperature at LOP Operating Pressure Minimum in Chiller Temperature at LOP Operating Pressure Minimum in Heat Pump Temperature at LOP Operating Pressure Minimum in Defrost Temperature at MOP Operating Pressure Maximum in Chiller Temperature at MOP Operating Pressure Maximum in Heat Pump Temperature at MOP Operating Pressure Maximum in Defrost Hdc03 DF-Proportional gain Auto DF-Integral time Auto SuperHeat deadzone +/- Auto Hdc04 Derivative time Auto Low SuperHeat int.time Auto Hdc05 LOP integral time Auto MOP integral time Auto Hdc06 MOP startup delay Auto Dynamic proportional gain? Hdc07 Blocked valve check Auto Hdc08 High Tcond.protection Auto 4: CABINET FLOADED 5: CABINET 0: NOT SELECTED 1: NONE or STAGES 2: CONTINUOS SLOW 3: CONTINUOS FAST 0: NOT SELECTED 1: PLATES 2: SHELL&TUBES 3: FINNED FAST 4: FINNED SLOW 0: NOT SELECTED 1: PLATES 2: SHELL&TUBES 3: FINNED FAST 4: FINNED SLOW Type R/W I R/W I R/W I R/W -2.0 °C -70.0 50.0 I R/W -18.0 °C -70.0 50.0 I R/W -3.0 °C -70.0 50.0 I R/W 12.0 °C -05.0 90.0 I R/W 12.0 °C -05.0 90.0 I R/W 15.0 °C -05.0 90.0 I R/W Upper SuperHeat Alarm Threshold in Auto 20.0 °C 0.0 99.9 I R Upper SuperHeat Alarm Threshold in Manual Percentage of maximum power managed by the valve in the circuit where it is installed (Chiller) (Auto) Percentage of maximum power managed by the valve in the circuit where it is installed (Chiller) (Manual) Proportional Factor of PID in Chiller (Auto) Proportional Factor of PID in Chiller (Manual) Integration Time for Superheating Control in Chiller (Auto) Integration Time for Superheating Control in Chiller (Manual) Percentage of maximum power managed by the valve in the circuit where it is installed (CP) (Auto) Percentage of maximum power managed by the valve in the circuit where it is installed (CP) (Manual) Proportional Factor of PID in CP (Auto) Proportional Factor of PID in CP (Manual) Integration Time for Superheating Control in CP (Auto) 0.0 °C 0.0 99.9 I R/W 0 % 0 999 I R 0 % 0 100 I R/W 0.0 0.0 ----- 0.0 0.0 99.9 99.9 I I R R/W 0 s 0 999 I R 0 s 0 999 I R/W 0 % 0 999 I R 0 % 0 100 I R/W 0.0 0.0 0 ----s 0.0 0.0 0 99.9 99.9 999 I I I R R/W R 0 s 0 999 I R/W 0 --- 0 999 I R Integration Time for Superheating Control in CP (Manual) DF-Circuit/EEV Ratio Auto Value description Percentage of maximum power managed by the valve in the circuit where it is installed (DF) (Auto) Percentage of maximum power managed by the valve in the circuit where it is installed (DF) (Manual) Proportional Factor of PID in DF (Auto) Proportional Factor of PID in DF (Manual) Integration Time for Superheating Control in DF (Auto) Integration Time for Superheating Control in DF (Manual) Dead Zone for PID Control (Auto) Dead Zone for PID Control (Manual) Derivative Time for PID (Auto) Derivative Time for PID (Manual) Integration Time for Low Superheating Control (Auto) Integration Time for Low Superheating Control (Manual) Integration Time for Low Evaporation Pressure Control (Auto) Integration Time for Low Evaporation Pressure Control (Manual) Integration Time for High Evaporation Pressure Control (Auto) Integration Time for High Evaporation Pressure Control (Manual) Duration of MOP Suspension (Auto) Duration of MOP Suspension (Manual) Attenuation Coefficient on Capacity Changes Time beyond which, under specific conditions, the valve is blocked (Auto) Time beyond which, under specific conditions, the valve is blocked (Manual) Maximum Condensation Temperature Value (Auto) Maximum Condensation Temperature Value (Manual) +030220741 Smart HP – rel. 1.0 - 05/09/2008 0 --- 0 100 I R/W 0.0 0.0 0 0 0.0 0.0 0.0 0.0 0.0 0.0 --------°C °C s s s s 0.0 0.0 0 0 0.0 0.0 0.0 0.0 0.0 0.0 99.9 99.9 999 999 9.9 9.9 99.9 99.9 99.9 30.0 I I I I I I I I I I R R/W R R/W R R/W R R/W R R/W 1.5 s 0.0 99.9 I R 0.0 s 0.0 25.5 I R/W 2.5 s 0.0 99.9 I R 0.0 s 0.0 25.5 I R/W 60 0 s s 0 0 999 999 I I R R/W 0 --- 0 1 D R/W 60 s 0 999 I R 0: NO 1: YES 0 s 0 999 I R/W 85.0 0.0 °C °C 0.0 0.0 99.9 99.9 I I R R/W 47 BMS addr.