Download TAKEDO
Transcript
A QUICK GUIDE TO PUTTING ON DUTY OPEN LOOP ASYNCHRONOUS MOTORS (without encoder) 1) Make all connections as indicated in the manual. 2) Check the following parameters: Parameter Description Unit SMS setting Value to be set Select according to country of use SMSLift Asyn Value SMS setting Value to be set Value 400 S6.1 Language Italian S6.2 Application SMSLift Asyn 3) Enter data in the following parameters: Parameter 4) Description Unit V P2.1.2 Motor Nominal Voltage P2.1.3 Motor Nominal Frequency Hz 50 Motor rating plate data Motor rating plate data P2.1.4 Motor Nominal Speed RPM 1440 Motor rating plate data P2.1.5 Motor Nominal Current A I Inverter Motor rating plate data P2.1.6 Motor Cos Phi 0.82 Motor rating plate data P2.1.7.1 Lift Rated Speed m/sec P2.1.7.2 Pulley Diameter mm 0.70 520 LIFT data LIFT data P2.1.7.3 Gear Ratio 1.58 LIFT data P2.1.7.4 Ropes Ratio 1:1 LIFT data P2.1.7.5 Update Data No Yes Run IDENTIFICATION Routine: - Set parameter P2.1.8 to 1 and run a call command: the contactors energizes, the brake doesn’t open, and “RUN” lights up. When the “RUN” light goes off, “STOP” appears and parameter P2.1.8 goes to 0, deactivate the call (e.g. by opening the operation valve). 5) If it does not work perfectly, see the full MANUAL. TAKEDO - 3VF NXP USER MANUAL Release P06 dated 20-07-2010 3