Download TAKEDO - 3VF - Taylor Lifts

Transcript
10
RUN ENABLE
MBC
TAKEDO–3VF NXP USER MANUAL Release P05 date 09-02-2009
RO3
RO2
NXOPTB5 BOARD
(3 N.O. RELAYS, SLOT D)
Imax<400mA ; Vmax<=125 Vdc
SPEED
DETECTOR RELAY
P2.7.7.3 = 11
MOTOR BLOCK
RELAY
P2.7.7.2 = 16
28
29
25
26
22
23
~
CONTACTORS
OPENING RELAY
P2.7.7.1 = 15
~
5(GND/AI2–)
RO1
OPTION −
BOARD
NXBR
ECONOMIZER
DEVICE FOR
BRAKE
+
19
18
3(GND/AI1–)
7(GND)
+24Vdc
I<250mA
4 (AI2+)
5(GND/AI2–)
18
4
1
2
6
10
TAKEDO 3VF
NXP
BRAKE Control
from Analog Output AO1
In order to enable it, set
P2.7.6.1 = 12 / ExtBrake
SAFETY BRAKE CONTROL
To activate it, set P2.6.3.4 = DigIn:A7
(terminal 2 configuration)
TP1
RUN ENABLE
1K2 1/4W
EMERGENCY OPERATION
9
8
16
15
14
19
To activate it , set
P2.3.3 = 2/NormClosed and P2.6.3.5 = DigIn:A8
(terminal 4 configuration)
TP
Ke2
DOWN-DOWNWARD
UP-UPWARD
MS-INSPECTION SPEED
LS-LOW SPEED
HS-HIGH SPEED
RUN ENABLE
LOGIC COMMAND
TP1
– OPERATING
VOLTAGE
TBM
OPERATION VOLTAGE +
Upstream the safety chain
230Vac
L3
L2
L1
MBC = Motor block contactor
MBC
MBC
BRAKE
207Vdc
I max 3A
˜
M
3-PH
SYNCHRONOUS MOTOR
Through the NXBR1 Board, ECONOMIZER DEVICE FOR
BRAKE, the brake is controlled by the inverter, supplied with full
voltage for 3 sec, then the supply goes down to half-voltage, to
prevent the over-heating of the brake coil during run.
TP
Note : Connection in case of brake control
input absence . II this case the terminal 5
(AI2-) have not to be connected together 3
and 7 terminals.
Signal
adapter
(if needed)
CAR LOAD CELL
OTHER OPTIONS