Download Addendum 1

Transcript
SECTION 27 5116
PUBLIC ADDRESS AND INTERCOMMUNICATION SYSTEMS
PART 1 -
GENERAL
1.01
SUMMARY
A.
B.
Principal items of Work in this Section include but are not limited to:
1.
Centralized racks, as indicated on the Drawings, containing a fully
operational public address (PA) system, intercommunication
system, and UPS. Features required include all-call paging, zone
paging, class-tone activation, intercom access to individual
speakers, phone to phone communications, radio and CD audio
distribution, and classroom phone outside line access to 911.
These features are accessible from the PBX, main PA phone,
classroom phone or audio microphone. System shall also provide
for interfacing with a master clock system for a class change
signaling system, and with a Fire Alarm system for override of the
tone signaling, PA audio, or both.
2.
Conductors, conduits, and terminal strips, including interface
cabling to PBX system, autonomous system overrides, Master
Clock system and the Fire Alarm system.
3.
Provide labor, engineering, design, testing, materials, supervision,
tools, mounting hardware, cable management, software and
components to provide a complete operable installation. The
system shall be installed in compliance with project documents,
applicable codes, manufacturer’s published recommendations, and
industry standards to deliver a system that meets standards of
quality and functionality.
4.
Provide services on Project site including specified connectivity
for administration areas, classrooms, computer and science
laboratories, libraries, auditoriums, multipurpose rooms, P.E.
areas, quad area, other instructional areas, and work areas as
indicated in Project Drawings.
Related Requirements:
1.
Division 01 - General Requirements.
2.
Section 26 0500: Common Work Results for Electrical.
3.
Section 26 0526: Grounding and Bonding.
4.
Section 26 0513: Basic Electrical Materials and Methods.
MODERNIZATION
OUR COMMUNITY SCHOOL
9/03/2014
PUBLIC ADDRESS AND INTERCOMMUNICATION SYSTEMS
27 5116-1