Message Type 0504 - Remote Call Connect
The following is the structure of a Type 0504 message line:
<Sync><0504>_<Call_Handler>_<Station>_<Data1>_<Data2>_<CR><LF>
<Call_Handler>
The 4 character Stentofon call handler accepting the remote call request with valid values from FFF0
through 9999 (leading Fs are used instead of 0s).
<Station>
This is a 4 character pager station number originating the call request with valid values from FFF0 through
9999 (leading Fs used instead of 0s).
<DataN>
Information that is not important to the Stentofon interface.
This message type defines a successful connection of the remote pager to the Stentofon Intercom System. Note
that many type 0507 messages for a station can occur before the connection is established. However, once the
connection is established, no further requests will be honored until the pager station has been disconnected.
Message Type 0206 - Call Disconnect
The following is the structure of a Type 0206 message line:
<Sync><0206>_<Call_Handler>_<CR><LF>
<Call_Handler>
This is the 4 character Stentofon call handler disconnecting a call with valid values from FFF0 through
9999 (leading Fs used instead of 0s).
This message type defines disconnection of a pager from the Stentofon Intercom System.