313 Message Type 0504 - Remote Call Connect The following is the structure of a Type 0504 message line: <Sync><0504>_<Call_Handler>_<Station>_<Data1>_<Data2>_<CR><LF> <Call_Handler> The 4 character Stentofon call handler accepting the remote call request with valid values from FFF0 through 9999 (leading Fs are used instead of 0s). <Station> This is a 4 character pager station number originating the call request with valid values from FFF0 through 9999 (leading Fs used instead of 0s). <DataN> Information that is not important to the Stentofon interface. This message type defines a successful connection of the remote pager to the Stentofon Intercom System. Note that many type 0507 messages for a station can occur before the connection is established. However, once the connection is established, no further requests will be honored until the pager station has been disconnected. Message Type 0206 - Call Disconnect The following is the structure of a Type 0206 message line: <Sync><0206>_<Call_Handler>_<CR><LF> <Call_Handler> This is the 4 character Stentofon call handler disconnecting a call with valid values from FFF0 through 9999 (leading Fs used instead of 0s). This message type defines disconnection of a pager from the Stentofon Intercom System.