Architectural and Engineering Specification
E.
4.9.3
A.
When call is answered the following shall occur:
- A connection tone is heard at both the receiving and calling station.
- The flashing green LED illuminates solid on the appropriate button if direct dial unit is used.
- The number and text of the station that is connected appears in the display.
- An in-use LED illuminates on the calling substation.
- Clear, two-way communication shall take place.
- Other calls from substations to the Control Room Master station during conversation shall
each flash their appropriate direct access button LED if direct dial unit is used, and sound the
call-in tone.
CALL FROM A CONTROL ROOM MASTER STATION TO ANY OTHER STATION
A call shall be placed from a CRM station to any other station in the system by dialling the
station number on the digit keypad or pressing the direct access key programmed for the actual
station.
B.
The display on the CRM station shall indicate the number and text of the called station.
C.
When calling any other master station, duplex hands-free loud-speaking communication shall
be possible between the two stations.
D.
When calling an elevator car or other security substation, the press-to-talk button shall be used
to control the conversation if needed for security purposes or privacy.
4.9.4
A.
GROUP CALL FROM A CONTROL ROOM MASTER STATION
A group call shall be initiated at a CRM station by dialling the number assigned to a preprogrammed group of stations or pressing the direct access key programmed for the actual
group. This shall sound an alert tone and allow paging to all stations in the group.
B.
There shall be no limitation to the number of stations in a group.
C.
Group calls shall have priority over other conversations in progress.
4.9.5
A.
PROGRAMMING BUTTONS ON THE CONTROL ROOM MASTER STATION
Direct access buttons on the CRM station shall be easily programmed and changed by the
station user.
B.
Once programmed, the button assignments shall remain in memory.
C.
This feature is valid if CRM is equipped with direct access button modules.
4.9.6 CONTROL DESK PC MANAGING PROGRAM
A. It shall be possible to use a PC with installed control managing program like AlphaVision to
manage all incoming call requests and outgoing calls by pointing and clicking on icons on the
site map on the screen.
B. The geographical location, call status and call priority of any station shall be clearly visible on
the map on the screen.
C. A call priority list and call log shall be available on the screen.
(Note to specifier: Describe other desired operations)
27
Aug. 2007