Download IP-Stepper
Transcript
NuBus Addressing The formula for conversion from VME to NuBus is: NuBus address = (VME address x 2) - 1 Standard Word I/O Accessing There are TWO motor control channels each of which has its own PCL-240MK motor controller and LS7166 counter chips. BOTH channels SHARE the Interrupt Vector and Sync Control registers. Byte Addresses are shown ( A0 is LSB ), but board is accessed on 16 bit word boundaries. Values are shown in HEX. MOTOR 1 CONTROL / STATUS MOTOR 1 DATA BITS 0-7 MOTOR 1 DATA BITS 8-15 MOTOR 1 DATA BITS 16-23 MOTOR 2 CONTROL / STATUS MOTOR 2 DATA BITS 0-7 MOTOR 2 DATA BITS 8-15 MOTOR 2 DATA BITS 16-23 COUNTER 1 DATA COUNTER 1 CONTROL COUNTER 2 DATA COUNTER 2 CONTROL CHANNEL 1 INTERRUPT REGISTER CHANNEL 1 POLARITY REGISTER CHANNEL 1 SOURCE REGISTER CHANNEL 2 INTERRUPT REGISTER CHANNEL 2 POLARITY REGISTER CHANNEL 2 SOURCE REGISTER SYNC CONTROL REGISTER INTERRUPT VECTOR REGISTER Figure 6 Base + 01 Base + 05 Base + 09 Base + 0D Base + 11 Base + 15 Base + 19 Base + 1D Base + 21 Base + 25 Base + 31 Base + 35 Base + 41 Base + 41 Base + 49 Base + 51 Base + 59 Base + 61 Base + 71 Base + 79 NuBus Word Access 17