Download Eddy Current Dynamometer Operator`s Manual
Transcript
ANTI-ROTATION SAFETY STOP There are two different styled anti-rotation safety stops depending upon whether it is a pedestal and base or enclosure type dynamometer. Pedestal and Base: 1. Check that the anti-rotation bracket is mounted securely to the base and encompasses the torque arm. 2. No adjustment is required. Enclosure Box: 1. Center torque arm with respect to dynamometer housing. 2. The torque and balance arms should be horizontal. 3. Adjust safety stop hex head screws for 1/8 inch clearance at top and bottom of torque arm and tighten jam nuts. NOTE: Safety stops are not intended to protect the load cell from shock. LOAD STRUT AND ROD ENDS A load strut with a rod end at each end connects the torque arm to the load cell to operate in tension or compression. To level torque arm, use the following procedure: 1. Disconnect rod end fitting from torque arm. 2. Adjust length of the load strut/rod end assembly. 3. Tighten jam nuts on rod end fittings and reconnect rod end to torque arm. NOTE: DS ships all dynamometers with the load cell disconnected from the torque arm. Dyne Systems • WATER-COOLED EDDY CURRENT DYNAMOMETERS DPD-002-04 • © Copyright Dyne Systems, Inc. 4 - Check & Adjust 29