Download OPERATION MANUAL
Transcript
Appendix C Auxiliary Area Address Function Settings A42600 Interrupt Task to Error, Unit A42611 Number An attempt was made to refresh a Special I/O Unit’s I/O from an interrupt task with IORF(097) while the Unit’s I/O is being refreshed by cyclic I/O refreshing (duplicate refreshing). A42600 to A42611: contain the Special I/O Unit’s unit number. These bits will be cleared when the error is cleared. Unit number: 000 to 05F (0 to 95) Cleared Cleared --- A40213 A42615 A42615 Interrupt Task Error Cause Flag When A40213 (the Interrupt Task 1: Duplicated Error Flag) is ON, this flag indicates refreshing the cause of the error. The CPU Unit will continue operating and the ERR/ ALM indicator on the front of the CPU Unit will flash. Cleared Cleared --- A40213, A42600 to A42611 A427 A42700 CPU Bus Unit to Setting Error, A42715 Unit Number Flags When an CPU Bus Unit Setting Error occurs, A40203 and the bit in this word corresponding to the Unit’s unit number are turned ON. Bits 00 to 15 correspond to unit numbers 0 to F. The CPU Unit will continue operating and the ERR/ALM indicator on the front of the CPU Unit will flash. 1: Setting error 0: No setting error Cleared Cleared Refreshed when power is turned ON or I/O is recognized. A40203 A428 to A433 A42800 Special I/O to Unit Setting A43315 Error, Unit Number Flags When a Special I/O Unit Setting Error occurs, A40202 and the bit in these words corresponding to the Unit’s unit number are turned ON. Bits 00 to 15 correspond to unit numbers 0 to F. (Bits A42800 to A43315 correspond to unit numbers 000 to 05F (0 to 95).) The CPU Unit will continue operating and the ERR/ALM indicator on the front of the CPU Unit will flash. 1: Setting error 0: No setting error Cleared Cleared Refreshed when power is turned ON or I/O is recognized. A40202 A440 All Max. Interrupt Contains the Maximum Interrupt Task Process- Task Processing Time in units of 0.1 ing Time ms. (This value is written after the interrupt task with the max. processing time is executed and cleared when PLC operation begins.) 0000 to FFFF Cleared hexadecimal Cleared See Function column. --- A441 All Interrupt Task With Max. Processing Time Contains the task number of the 8000 to 80FF interrupt task with the maximum pro- hexadecimal cessing time. Hexadecimal values 8000 to 80FF correspond to task numbers 00 to FF. Bit 15 is turned ON when an interrupt has occurred. (This value is written after the interrupt task with the max. processing time is executed and cleared when PLC operation begins.) Cleared Cleared See Function column. --- A444 All Pulse Output 0 Stop Error Code When a pulse output stop error --occurred with pulse output 0, the corresponding error code is written to this word. --- Cleared --- Pulse Output 1 Stop Error Code When a pulse output stop error --occurred with pulse output 1, the corresponding error code is written to this word. --- Refreshed when origin search starts. Refreshed when a pulse output stop error occurs. Words A426 A445 474 Name Bits Status after mode change Status at startup Write timing Related flags, settings ---
Related documents
Version 1.9
SYSMAC CJ Series CJ1G CPU## Programmable Controllers
CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC
OPERATION MANUAL
PROGRAMMING MANUAL Programmable Controllers
CS/CJ Series Programmable Controllers
CX-Programmer Operation Manual
Série CJ E/S intégrées UCs CJ1M-CPU21/22/23 Manuel d`utilisation
User Manual - FTP Directory Listing
Omron CS1D PCS User Manual
User Manual D637-R/D639-R Series Servo Valves
Automates programmables MANUEL D`UTILISATION