Connecting the VS-88SDI Figure 7: Device Properties Screen 4. If required, make changes and press Set. If not, click Close. 6.7 Controlling via the Ethernet Port You can control the VS-88SDI via RS-232/RS-485 or the Ethernet using the Kramer K-Router application. If you are controlling a standalone unit via RS-232 or the Ethernet, configure the unit as master (Mach No. 1), see section 6.1.1. 6.8 Using the Ethernet Reset Button To reset Ethernet parameters to the factory defaults: 1. Turn the power switch OFF and then ON while pressing the ETH RESET button. 2. The unit powers up and loads its memory with the factory default definitions. 3. The unit also erases all stored presets, returns to the default Protocol 3000 and indicates “F-rst” on the 7-segment display. 17